FPS3000 SERIES INSTRUCTION MANUAL
FPS3000 SERIES SPECIFICATIONS
1 Rated output voltage
2 Output voltage set point
3 Output voltage range
4 Maximum Output Current. Refer to Fig. 1
5 Maximum output power
6 Input voltage / frequency range
7 AC input connector
8 Maximum input current (at 100/200Vac)
9 Power Factor (Typ)
10 Efficiency (Typ)
11 Inrush current
12 Hold-up time
13 Maximum line regulation
14 Max load regulation
15 Output noise P-t-P
16 Temperature stability
17 Temperature coefficient
18 Remote sensing
19 Parallel operation
20 Series operation
21 Over current protection
22 Over voltage protection (*9)
23 Over temperature protection
24 Remote On/Off control
25 DC OK signal
26 Over-Temp. warning
27 AC fail signal
28 Auxiliary power supply
29 Vout voltage trimming
30 Front panel indicators
31 I²C Interface
32 Operating temperatue
33 Storage temperature
34 Operating humidity
35 Storage humidity
36 Cooling
37 Vibration
38 Shock
39 Conducted emission
40 Radiated emission
41 Applicable safety standards
42 Withstand voltage
43 Isolation resistance
44 Leakage current
45 Weight (Typ)
46 Size (W*H*D)
Notes:
*1:
For input voltage lower than 100Vac, maximum output power derated by 10%.
*2:
For cases where conformance to various safety standards (UL, EN etc.) is required, to be described
as 100-240Vac (50/60Hz).
*3: At 100/200Vac, rated load and 25˚C ambient temperature.
*4: Not applicable for the noise filter inrush current less than 0.2mS.
*5:
From 85~132Vac or 170~265Vac, constant load.
*6:
From No-load to Rated load, constant input voltage. Measured at the sensing point in Remote sense.
*7: Measured with JEITA RC-9131A 1:1 probe, 20MHz B.W.
*8:
Remote sensing can compensate up to 1V drop on each load wire.
*9: Inverter shut down method. Reset by AC voltage recycle or by On/Off control.
*10: For each installed FPS1000 unit.
V/I FPS3000-12 FPS3000-24 FPS3000-32 FPS3000-48
V1
12V
24V
V2
13.2V
29V
I1
198A
99A
I2
216A
120A
FPS3000-12
V
12
V
12+/-1%
V
10.5~13.2
A
216
(*1)
W
2592
(*2)
---
85~265Vrms continuous, 47~63Hz, Single phase
FPS3000: Three IEC320 inlets at the rear panel (Refer to outline drawing)
---
FPS3000/P: IEC320 inlet at each FPS1000 unit front panel.
FPS3000/TB: 3 WAY Terminal Block inlet.
FPS3000 or FPS3000/P: 12.0/6.0 for each FPS1000 unit installed
A
FPS3000/TB: 36.0/18.0 for full rack
---
>0.98 at 115/230V and maximum output power for each AC input
(*3)
%
81/83
(*4)
A
Less than 40A for each input
mS
20mS typical, at 100Vac input, rated output voltage and less than 80% of rated load
(*5)
---
0.40%
(*6)
---
0.80%
(*7)
mV
150
---
0.1% of rated Vout for 8hrs after 30min warm-up. Constant line,load and temperature.
PPM/°C 200
(*8)
V
Possible. Refer to Instruction Manual.
---
Possible. Refer to Instruction Manual.
---
Possible. Refer to Instruction Manual.
---
105~125% of maximum output current. Refer to Fig. 1
(*10)
V
14.3~15.7
(*10)
---
Inverter shut down method, automatic reset.
(*10)
---
By electrical signal or dry contact. ON: 0~0.6V or short. OFF: 2~15V or open.
(*10)
---
Open collector signal. On when Vout>80+/-5% rated output. Max.sink current: 10mA
(*10)
---
Open collector signal. Refer to Instruction Manual.
(*10)
---
Open collector signal. Refer to Instruction Manual.
---
11.2~12.5VDC. 0.75A Maximum output current.
(*10)
---
Possible, via Vout Trim pin in the I/O connector.
---
For each installed FPS1000 unit. AC OK, DC OK, DC FAIL
---
Optional. Refer to Instruction Manual.
---
0~50°C: 100% load. Derate 2%/°C, 50°C to 60°C.
---
-30~85°C
---
10~90% RH, no condensation.
---
10~95% RH, no condensation.
---
By internal Fans in each installed FPS1000 unit. Variable speed control.
---
Built to meet ETS 300 019
---
Built to meet ETS 300 019
---
Built to meet EN55032B, FCC part 15J-B, VCCI-B. For each AC input.
---
Built to meet EN55032B, FCC part 15J-B, VCCI-B
---
IEC 62368-1 UL62368-1 CSA22.2 No.62368-1 EN62368-1.
---
Input-Output: 3000Vrms, 1min. Input-Ground: 2000Vrms, 1min. Output-Ground: 500Vrms, 1min.
---
More than 100Mohm at 25°C and 70% RH. Output-Ground: 500Vdc
FPS3000 or FPS3000/P: For each AC input. Less Than 1.1mA at 230Vac.
mA
FPS3000/TB: Less Than 3.5mA at 230Vac.
Kg
10.0
---
440x44x351mm. Refer to Outline Drawing.
32V
48V
38.4V
58V
78A
51.75A
93A
63A
FPS3000-24
FPS3000-32
24
32
24+/-1%
32+/-1%
21.5~29.0
28.8~38.4
120
93
2880
2976
84/86
84/86
200
250
31~34
41.5~45.5
Vout (V)
V2
V1
I1
Fig. 1: Rated output current
FPS3000-48
48
48+/-1%
43.0~58.0
63
3000
85/88
300
62~66
Iout (A)
I2
21