SAFETY INSTRUCTIONS
1. FUSES MUST BE CHANGED BY AUTHORIZED SERVICE PERSONNEL ONLY!
F1:
T1.6A
250V
F2, F3 4A
250V
2. POWER SUPPLY MUST BE SECURED TO THE CHASSIS OF THE END USE EQUIPMENT BY 3 SCREWS INSERTED INTO THREADED
OPENINGS IN THE BOTTOM OF THE POWER SUPPLY ENCLOSURE (REFER TO OUTLINE DRWG.)
3. MAX LEAKAGE CURRENT OF THE END USE EQUIPMENT SHOULD NOT EXCEED 3.5mA.
4. DISCONNECT DEVICE
An appropriate disconnect device for this product shall be provided by the end equipment or as part of the building
Furthermore, the disconnect device must have a contact separation of at least 3mm, and must disconnect both poles of the input
supply simultaneously.
In all cases, the main disconnect device of this product must be easily accessible and identifiable. Examples of an appropriate
disconnect device are: an isolating switch with the on and off positions appropriately marked, a circuit breaker inside the building
installation, the power supply cord or appliance coupler, etc.
CE MARK
CE Marking when applied to a product covered by this handbook indicates compliance with the Low Voltage Directive (LVD) of the
European Union in that it complies with EN 62368-1.
CE "Declaration of Conformity" in accordance with the preceding directive and standard has been made and is on file at our EU
representative: TDK-Lambda Germany GmbH, Karl-Bold-Str. 40, D-77855 Achern.
UKCA Marking, when applied to a product covered by this handbook, indicates compliance with the Electrical Equipment (safety)
Regulations 2016,
Electromagnetic Compatibility Regulations 2016 and Restriction of the Use of Certain Hazardous Substances in Electrical & Electronic
Equipment regulation 2012.
UKCA "Declaration of Conformity" in accordance with the preceding directives and standards has been made and is available on a file
at our UK representative TDK-Lambda UK Limited, Kingsley Avenue, Ilfracombe, Devon EX34 8ES.
Declaration
s may be accessed
emea
via company web site
www.
manual.
.tdk-lambda.com/
4
installation.,