Télécharger Imprimer la page

La Sommeliere CTVNE142A Notice D'utilisation page 40

Masquer les pouces Voir aussi pour CTVNE142A:

Publicité

Les langues disponibles

Les langues disponibles

5.
Display of temperature value: in normal state, the set temperature value is displayed on the screen. Press "lock" key
for taking a look of actual temperature value.
6.
Display of humidity value:
When the humidity level is under 40%, the screen will display 40% and alarm will work. The warning icon
appear.
When the humidity level is between 40%(including 40%)and 80%(including 80%), LED displays the actual humidity value.
When the humidity level is above 80%, LED will display 80% and the alarm will work. The warning icon
appear
7.
Lock : press and hold lock key
lock. None of the parameter is allowed to be modified or examined in the state of lock. Remove the locked state, then
press the lock button for 3 seconds.
8.
Expiration (graphite stopper reminder): press the set key
using time for 10 seconds, as the chart shows that the use of time D (day), H (Hour), M (minutes) will be displayed, each
will be displayed for 5 seconds. For example when viewing, detect carbon plug using time is 360 days 11 hours 22 minutes,
then the first 5 seconds, the display 360 of this figure (Table 1), and then displays the two numbers 11 and 22 for 5 seconds
(Table2) . Press the set key
and carbon Icon will disappear from the screen. The icon of reminding you to change Carbon filter will appear and the
alarm will work if it is used for more than 365 days.
9.
Degrees Fahrenheit and Celsius transformation: press up and down button
for 3s, the screen will display the icon of lock. Disappearing of this icon means release
and lighting button
39
and the lighting button
at the same time for 3 seconds, the using time will be reset
at the same time, show
at the same time for 3 seconds.
will
will

Publicité

loading