TECHNICAL DATA
Definition in accordance with EN
Constructive system
Nominal power in kW
Efficiency in %
Smoke outlet diameter in mm
Chimney height ≥ (m) - dimension (mm)
Chimney draught in Pa (mm H
Hourly wood consumption in kg / h (wood with 20% humidity)
CO measured at 13% oxygen in %
Exhaust gas emission in g/s – wood
Exhaust gas temperature in °C - wood
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg
Fire prevention safety distances
Heatable m
(30 kcal/h x m
3
(*) The proposed value are indicative. The installation must, in any case, be sized and verified according to the general calculation method in UNI
EN13384-1 or by another method of proven efficiency.
(**) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume of the product
is: favourable type of building (30 kcal/h x m
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating, in
the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
ThE dEclarEd TEchNIcal daTa havE bEEN achIEvEd by bUrNINg bEEch wood class "a1" accordINg To ThE rEqUIrEmENT
UNI EN Iso 17225-5 aNd wood moIsTUrE coNTENT lEss ThaN 20%. by bUrNINg a dIFFErENT kINd oF wood ThE EFFIcIENcy
oF ThE prodUcT ITsElF coUld chaNgE aNd somE spEcIFIc adjUsTmENTs oN ThE applIaNcE coUld bE NEEdEd.
O)
2
)
3
); less favourable type of building (40 kcal/h x m
3
CANDY 4.0
EN 13240
1
6,2
85,1
120
1,7
0,04 - 500 mg/m
5,6
229
233 x 315
330 x 356 x 215
/
890
404
397
85
177 (**)
); unfavourable type of building (50 kcal/h x m
3
ENGLISH
BRIGITTA GB
EN 13240
1
4,7
81
120
(*) 4 - 200x200 Ø200
12 ( 1,2 mm H
O)
2
1,35
0,08 - 1000 mg/m
3
4,6
226
233 x 214
330 x 294 x 215
/
Movable - flat
640
404
397
70
Chapter FIRE SAFETY
134 (**)
3
).
3
25