8.1 What to do if...
Problem
The appliance does not
operate.
The appliance is noisy.
The compressor operates
continually.
The compressor does not
start immediately after
pressing the "Super
Freeze", or after changing
the temperature.
Door is misaligned or inter‐
feres with ventilation grill.
Door does not open easily. You attempted to re-open
The lamp does not work.
Possible cause
The appliance is switched
off.
The mains plug is not con‐
nected to the mains socket
correctly.
There is no voltage in the
mains socket.
The appliance is not sup‐
ported properly.
Temperature is set incor‐
rectly.
Many food products were
put in at the same time.
The room temperature is
too high.
Food products placed in
the appliance were too
warm.
The door is not closed cor‐
rectly.
The Super Freeze function
is switched on.
The compressor starts af‐
ter a period of time.
The appliance is not level‐
led.
the door immediately after
closing.
The lamp is in stand-by
mode.
The lamp is defective.
ENGLISH
Solution
Switch on the appliance.
Connect the mains plug to
the mains socket correctly.
Connect a different electri‐
cal appliance to the mains
socket. Contact a qualified
electrician.
Check if the appliance
stands stable.
Refer to "Operation" chap‐
ter.
Wait a few hours and then
check the temperature
again.
Refer to "Installation" chap‐
ter.
Allow food products to cool
to room temperature be‐
fore storing.
Refer to "Closing the door"
section.
Refer to "Super Freeze
function" section.
This is normal, no error
has occurred.
Refer to installation instruc‐
tions.
Wait a few seconds be‐
tween closing and re-open‐
ing of the door.
Close and open the door.
Contact the nearest Au‐
thorized Service Centre.