18
Troubleshooting
 
Error code
E1
E2 / E3
EE
Cause
Fault with
temperature sensor on evaporator
Error on air humidity
and temperature sensor
Leak in the cooling circuit
Solution
The device is working again, but de-icing
is carried out approx. every 20 minutes
and takes up to 8 minutes.
If the device is currently not carrying out
de-icing, briefly disconnect the device
from the mains network. If the error
persists after restarting, contact customer
service.
The device is working again and dehumi-
difies on a continuous basis, irrespective
of a humidity.
Humidity and temperature sensor must
be replaced, if required. Contact customer
service.
Briefly disconnect the device from the
mains network.
If the error persists after restarting,
contact customer service.