Télécharger Imprimer la page

TDK-Lambda ZPS20 Mode D'emploi page 13

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
ZPS20 Installation Manual
Special Safety Instructions:
Standard Specific Safety Instructions:
Whilst all individual outputs are classed as SELV outputs in accordance with the standard IEC/EN/UL/CSA60950-1
(<60Vdc or 42.4V peak), seriesed combinations of these outputs may exceed these
values and become hazardous output voltages.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment
may be impaired.
Environmental Specifications:
Description
Operation
Storage
Use
Indoor
-
0°C - +70°C (derating at 2.5%/°C from 50°C)
Temperature
(For ZPSA40/60 -3,-5,-9)
-20°C - +85°C
0°C - +70°C derating at 2.5%/°C from 40°C)
Humidity
10 - 95% RH, non-condensing
10 - 95% RH, non-
condensing
Altitude
2000M
2000M
Orientation
See Fig 1
ALL
Material Group
IIIb
Pollution Degree
2
IP Protection Class
IPX0
Level of Insulation:
Dielectric Strength testing is carried out as follows:
Primary mains to earth: 1.5kVAC
Primary mains circuits to secondary: 3kVAC, 4142VDC
Output to earth isolation 500VDC
.Safety Approvals:
nd
UL/cUL60950-1 (2
Edition)
nd
IEC / EN60950-1(2
Edition)
CE marking when applied to any ZPSxx-yy product indicates compliance with the Low Voltage Directive
nd
(2006/95/EC) in that it complies with EN60950-1 (2
Edition).
Fusing: Internal fuses (F1): Single fuse in the L line, T2A, 250V,
Input Connection
ACN – Neutral ACL – Live
Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal
ZPS20 –xx