Télécharger Imprimer la page

TDK-Lambda CUS200LD Manuel D'installation page 14

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
1. Model name identification method
CUS 200LD - 5 /
2. Terminal Explanation
L
: Input terminal Live line (Fuse in line)
N : Input terminal Neutral line
: Earth terminal
+V : + Output terminal (20A max. / terminal)
-V : - Output terminal (20A max. / terminal)
Output voltage adjustment trimmer
Output monitoring indicator (Green LED)
Mounting hole (hole diameter:
*All screws size is M3.0.
3. Connecting method
Pay attention to the input wiring. If it is connected to wrong terminal, the power supply will be damaged.
Input must be off when making connections.
Connect
terminal to earth (frame ground of the equipment etc.) by thick wire for safety and improvement
of noise sensitivity.
Recommended torque :M3.0 screw0.50N·m (5.1kgf·cm) ~ 0.70N·m (7.1kgf·cm)
Option (*1)
(*1) Designation for Optional models, blank for
Standard model
Rated Output Voltage
Output Power type
Series Name
3.8mm)