5. WIRING
5.1. Disconnect a probe
To disconnect a probe, please follow these instructions:
1
FR
EN
2
3
Using a suitable screwdriver,
unscrew the terminal block to
detach the wires
CAUTION: To maintain the IP 68 it is important to screw the cable glands fully and screw the screws with a PZ.1 head
and a tightening torque of 0.9 N.m.
As a reminder the probe 1 is on the rounded side of the housing, the probe 2 is on the flat side of the housing.
Remove the
screws
1
5V + -
1 2 3 4
Unscrew the cable
gland to loosen
the cable
2
2
1
5V + -
1 2 3 4
4
5V + -
1 2 3 4
Once the cable has been removed, insert the
gland plug provided in the package to maintain
the watertightness of the product
Open the product by
pulling on the cable
gland
WARNING : do not
pull on the wires