1.5. Technical specifications
1.5.1 General characteristics
Parameters
Working temperature
Dimensions
Weight
Casing
Radio standards
LoRaWAN network
LoRaWAN class
Max power transmission
Applicative port number (downlink)
Daily clock drift at 25°C
1.5.2 Electric characteristics
Supply
Battery
FANSO ER18505H+W36mm+51021 connector
External
USB
The external power supply chosen must comply with the above electrical characteristics and must conform to the standards EN/IEC 62368-1 and
EN 61000-3-2, EN 61000-4-2, EN 61000-4-4, EN 61000-4-5.
Example of reference tested by adeunis and functional with the product by cutting the wires: GS05E-USB - Wall Mount AC Adapters 5W 5V 1A
W/Euro Plug WallMount USB Output from Mean well.
1.5.3 Probes characteristics
Characteristics
Ambient probe - temperature range
Remote probe - sensor temperature range
Remote probe - wire temperature range
Remote probe - wire length
Precision [0°C/+60°C]
Precision [-35°C/0°C]
Precision [-55°C/-35°C]
Precision [+60°C/105°C]
CAUTION: Allow a few minutes for the probe to come back to room temperature before any manual operations to avoid mechanical damages.
In addition, please respect the minimum and maximum temperatures for the sensor and the wire (cf. Table here-above).
Value
-25°C / +70°C
132 x 62 x 34mm
148g 1 Remote probe, 185g 2 remote probes
IP 68
EN300220-1 et EN300220-2
EU863-870
Class A and Class C (if power by external supply)
14 dBm
1
5 to 7 seconds
Characteristics
Voltage
Current max
Input range
Current max
Tension
Courrent max
[-25°C /+70°C]
-55°C..+155°C
-30°C+105°C
+/- 0,2°C
+/- 0,5°C
-0,6 /+0,8°C
+/- 2°C
Value
Unit
3.6
V
150
mA
4.5 to 6.5
V
110
mA
5
V
110
mA
2m
FR
EN
43 of 61