= ENGLISH =
FLOW RATE
min - max
l/min
15 – 190
g.p.m.
3,9 – 50,1
(USA)
«Translated from original instructions»
THIS DOCUMENT PROVIDES THE INSTRUCTIONS FOR
THE INSTALLATION, USE AND MAINTENANCE OF THE
VALVE, THEREFORE IT IS AN INTEGRAL PART OF
THE VALVE ITSELF AND MUST BE READ CAREFULLY
BEFORE ANY USE AND KEPT WITH CARE.
STRICTLY
COMPLY
CONTAINED IN THIS DOCUMENT IN VIEW OF A SAFE
AND EFFECTIVE USE OF THE VALVE.
FAILURE TO COMPLY WITH THESE INSTRUCTIONS
MIGHT CAUSE EARLY FAULTS AND RESULT IN
SITUATIONS OF DANGER, IN ADDITION TO VOIDING
ANY WARRANTY.
1- GENERAL INFORMATION
1.1- The SV2 or SX2 relief valve is a manually-
adjustable, pressure-operated device which, according
to its setting, releases the excess of water when the
pressure inside the pump/system exceeds the adjusted
value, thus reducing the pressure. The normal working
conditions can be restored by turning off and then
restarting the system.
1.2- Since the SV2 or SX2 valve is used in connection
with a high pressure water pump/system, which shall be
called hereafter only "system", installation and use must
be suited to the type of system used and comply with
the safety Regulations in force in the Country where the
valve is used.
1.3- Before using the valve, make sure that the system
the valve is used with is certified to comply with the
relevant Directives and/or Regulations.
1.4- Before installing and using the valve for the first
time, we suggest you check that it is undamaged and
make sure that the rated features correspond to the
required ones. If this is not the case, do not use the
valve and contact the after-sales service of Interpump
Group for information.
2- PACKAGE
2.1- Packages must be handled in compliance with the
instructions stated on the packages themselves and/or
provided by the manufacturer.
2.2- In case the valve is not used immediately, it must
be stored in its integral package and placed in areas
which are not exposed to the weather and which are
protected from excessive humidity and from direct
TECHNICAL FEATURES
SETTING PRESSURE
RANGE
-SP-
min - max
6 – 72
60 – 720
870 – 10442
WITH
THE
INSTRUCTIONS
max WORKING
PRESSURE
-WP-
MPa
60
bar
600
p.s.i.
8700
sunlight. Moreover, it is advisable to place wooden
pallets or other types of pallets between the package
and the floor, in order to prevent the direct contact with
the ground.
2.3- The package components must be disposed of in
compliance with the relevant laws in force.
3- INSTRUCTIONS FOR INSTALLATION:
3.1- The setting pressure (SP) is adjusted and fixed
by sealing by Interpump Group and cannot be
changed. The values of the setting pressure and
suggested maximum working pressure (WP) are
stated on the valve.
3.2- The maximum flow rate depends on the setting
pressure and ranges from 15 to 190 l/min. The exact
value is stated on the valve.
3.3- The setting pressure (SP) is the pressure at which
the valve opens, thus determining the maximum
pressure value that the system cannot exceed.
3.4- The installation must be made by qualified and
authorized staff only, who must have the required skills
to handle high pressure systems and be informed of the
operating and safety instructions contained in this
document.
3.5- Before installing the valve, slightly lubricate the
G1/2 thread with a grease specific for very high
pressures (EP-extreme pressure) containing Graphite
or Molybdenum, then tighten the fitting by means of a
dynamometric wrench (90 Nm).
3.6- In order to ensure the seal of the G1/2 fitting, fit a
metal washer with a rubber ring between the fittings, or
use a proper sealant on the thread.
IMPORTANT: During use, never exceed
the maximum values of pressure, flow-
rate and temperature as stated in this
document and/or indicated on the valve.
IMPORTANT: For a correct use of the
valve, it is necessary to install it in the
area of the system reaching the higher
pressure
suggest you install it by the component
that you wish to protect most from
pressure peaks.
-
-
7
TEMP.
max
°C
°F
MPa
bar
60
140
p.s.i.
during
use.
Moreover,
MASS
kg
lbs
1,5
3,4
we