ENERMAX Platimax Series Power Supply Specification
AC Input Voltage
AC Input Current
3.3V
5V
12V
-12V
5Vsb
Total Power
Peak Power*
Over Current Protection
(DC)
Under Voltage / Over Voltage
Protection
Over Power Protection
Over Temperature Protection
Short Circuit Protection
Surge & Inrush Protection
Temperature
Humidity
MTBF
Dimension
Weight
Safety
EMC
* Peak power may last up to 60 seconds.
EPM1000EWT
115-240VAC, 50-60Hz
(Maximum range: 100-264VAC, 47-63Hz)
DC Output
Rated
0-20A
0-20A
0-83A
0-0.5A
0-3A
Protection Circuit
DC Rail
3.3V
5V
DC Rail
UVP trigger range
3.3V
5V
12V
Activated when output power > 120 ~150% of rated max load.
Activated when PSU heat sink > 90 ~ 120
Activated when any DC rails short-circuited.
Sustain 2KV surge stroke.
Sustain up to 100A inrush current @ 240VAC at cold start.
ENVIRONMENT
Operation ambient: 0~50
Storage ambient: -40~70
Operation: to 85% relative humidity, non-condensing at 25
Storage: to 95% relative humidity, non-condensing at 50
OTHERS
> 100,000 hours at 70% of full rated load, 230VAC/50Hz, 25
(MIL-HDBK-217F standard)
150 (w) x 86 (h) x 175 (d) mm
2.25kg (without modular cables) ±50g
UL/cUL(Level 6), TUV, GOST, CB, BSMI
CE, FCC, KCC
2
10.5-4.5A
Combined
100W
996W
6W
15W
1000W
1100W
OCP trigger range
30 – 40A
30 – 40A
OVP trigger range
2.0 – 2.4V
3.3 – 3.7V
8.5 – 9.5V
o
C.
o
C
o
C
3.9 – 4.5V
5.7 – 6.5V
13.3 – 14.5V
o
C
o
C
o
C