Product HANDBOOK
Special Safety Instructions
Standard Specific Safety Instructions:
Whilst all individual outputs are classed as SELV outputs in accordance with the standard
IEC/EN/UL/CSA60950-1 (<60Vdc or 42.4V peak), seriesed combinations of these outputs may exceed these
values and become hazardous output voltages.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
If the units are to be installed as Direct Plug-in Power Units and full compliance to UL1310 is required, the
units must be installed in an airtight distributor box that conforms to the requirements of UL1310.
Environmental Specifications:
Description
Use
Temperature
Humidity
Altitude
Orientation
Material Group
Pollution Degree
Class
Level of Insulation:
Dielectric Strength testing is carried out as follows:
Primary mains circuit to earth: - 1500KVAC, 2121VDC
Primary mains circuits to secondary: 3kVAC, 4142VDC*
*This test is not possible with Y capacitors fitted to the unit as damage to these
capacitors will occur. It is also necessary to short circuit the output together and to earth.
Safety Approvals:
UL508
nd
UL/cUL60950-1 (2
Edition)
nd
IEC / EN60950-1(2
Edition)
CE marking when applied to any DSP60-xx product indicates compliance with the Low Voltage Directive
(2006/95/EC) in that it complies with EN60950-1 (2
complies with EN61024-3, EN61000-6-3, EN61000-6-2 and EN55024.
Warning: This is a Class A product. In a residential, commercial or light industrial environment it may cause
radio interference. This product is not intended to be installed in a residential environment; in a commercial
and light industrial environment with connection to the public mains supply, the user may be required to take
adequate measures to reduce interference.
Fusing: Internal fuses (F1): Single fuse in the L line, T2AH, 250V, 5x20mm.
Symbols:
N
AC
N – Neutral
If the earth terminal of the DSP60-XX PSU is connected to the main incoming earth conductor of the end
equipment, the installer must cover the earth symbol with a label bearing the earth symbol of IEC60417-5019.
Page 13 of 16
DSP60-xx
Operation
Indoor
-25° C - +71° C (derating at 2.5%/° C from 55° C)
20 - 95% RH, non-condensing
See Fig 1
II (Double insulated no earth connection required)
nd
L
L – Live
2000M
IIIb
2
Edition) and the EMC Directive 2004/108/EC in that it
DSP60 Series, 23417 issue 03 April 2015
Storage
-
-25° C - +85° C
20 - 95% RH, non-
condensing
ALL