DPP480-xx-1
Product HANDBOOK
Mechanical Outline Drawings:
Front panel indicators:
DC ON - The Green LED is on when the output voltage is >75%.
DC LOW - The red LED is on when the output voltage is between 70 – 90%.
The output can be increased by turning the front panel potentiometer clockwise, turning the potentiometer
counter clockwise will decrease the output.
Adjusting output voltage beyond the stated range may cause overvoltage protection (OVP) to clamp the
output.
To reset for normal operation simply adjust the potentiometer to reduce the output voltage to within its
range (see table above)
Power ready signal (Rdy) 24V model only.
Contact closed at start up – threshold voltage 17.6 – 19.4Vdc
Contact electrical isolation 500Vdc
Contact rating 60Vdc/0.3A
Weight: DPP480-xx-1 weighs 1920g
TDK-Lambda UK Ltd
Kingsley Avenue, Ilfracombe
Devon, EX34 8ES
Telephone - Sales and Service +44 (0)1271 856666
Head Office and Works +44 (0)1271 856600
Facsimile +44 (0)1271 864894
WEBSITE:
www.uk.tdk-lambda.com
Page 16 of 16
DPP480-xx-1, 23421 issue 04, December 2015