7.10 MAINTENANCE TO BE PERFORMED BY AN AUTHORISED TECHNICIAN
Task
General professional inspection
and servicing of the stove (& the
flue)
Clean/sweep the flue gas system
Replacement of parts that are not
mentioned in this manual
Check the connection between the
stove and chimney/the flue
All other service work not specifi-
cally mentioned in this manual.
Clean the room blower/flue blow-
er
Cleaning the stove inside and out
Lubricate the pellet auger gear
unit
Clean the smoke chamber
Check the ignition element
Clean the air side of the heat ex-
changer
Clean the flue side of the heat ex-
changer
Check the electrical parts such as
the PCB, the wiring, the sensors
and safety devices.
Check the silicon hoses on the pres-
sure sensor
Check the door seal and replace if
necessary.
Test the stove at all 5 combustion
levels
Test the safety devices
(*) The specified frequency is a minimum. Local law and/or your insurance contract
may prevail depending on which is stricter. If the stove is used intensively, the flue
must be cleaned more frequently.
Frequency*
Twice a season; the first time at the start
of the season and/or after 900 combustion
hours, when the stove displays SERV
Twice a season; the first time at the start of
the season
When damage is identified
Twice a season; the first time at the start
of the season and/or after 900 combustion
hours, when the stove displays SERV
Once a season at the start of the season
Twice a season; the first time at the start
of the season and/or after 900 combustion
hours, when the stove displays SERV
Once a season or after 900 combustion
hours when the stove displays SERV
Once a season at the end of the season
Once a season; at the end of the season or
after 900 combustion hours when the stove
displays SERV
Once a season
Once a season or after 900 combustion
hours when the stove displays SERV
Once a season or after 900 combustion
hours when the stove displays SERV
Once a season or after 900 combustion
hours when the stove displays SERV
Once a season or after 900 combustion
hours when the stove displays SERV
Twice a season; the first time at the start of
the season or after 900 combustion hours
when the stove displays SERV
Once a season or after 900 combustion
hours when the stove displays SERV
Once a season or after 900 combustion
hours when the stove displays SERV
4
165