24
A
Caution!
The condensate contains oil
and must be disposed of at a proper
collecting point.
•
Clean air filter element (25) of filter/
regulator unit.
25
•
Drain the condensate from the filter/
regulator unit into a container (26).
A
Caution!
The condensate contains oil
and must be disposed of at a proper
collecting point.
Every 250 operating hours
•
Replace air intake filter element of
compressor pump.
•
Replace air filter element of filter/
regulator unit.
Every 500 operating hours
•
Change the crankcase oil.
Every 1000 operating hours
•
Have unit serviced by an authorized
service station. This will extent the
compressor's service life considera-
bly.
5.2
Device storage
1.
Switch unit OFF and unplug.
2.
Release pressure from tank and all
connected air tools.
3.
Store device in such way that it can-
not be started by unauthorized per-
sons.
A
Caution!
Do not store device unpro-
tected outdoors or in damp environ-
ment. Do not lay device on its side for
transportation or storing.
6. Trouble Shooting
A
Danger!
Prior to all servicing:
− Switch Off.
− Unplug.
− Wait until the device has come to
a complete stop.
− Ensure the device and all air tools
and accessories connected to it
are relieved from pressure.
− Let the device and all air tools
and accessories used cool off.
After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts remain on or in the device.
Compressor does not run:
•
No mains voltage.
− Check cables, plug, outlet and
mains fuse.
•
Mains voltage too low.
− Use only extension cables with
sufficient lead cross section (see
26
"Technical Specifications"). Avoid
using extension cable with cold
device.
•
Compressor
unplugging.
− Switch compressor OFF at the
On/Off switch, then ON again.
•
Motor has overheated, caused by
insufficient cooling (cooling fins
covered).
− Remove cause for overheating
and allow to cool down for
approx. 10 minutes, then start
again.
Compressor runs but does not build
up sufficient pressure.
•
Condensate drain of pressure ves-
sel leaky.
− Check gasket of drain screw(s);
replace if necessary.
− Tighten drain screw(s) fingertight.
•
Drain cock on cup of filter/regulator
unit open.
− Tighten drain screw fingertight.
Air tool is not supplied with sufficient
pressure.
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
The device's packaging can be 100 %
recycled.
Worn out devices and accessories con-
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled.
These instructions are printed on chlo-
rine-free bleached paper.
was
stopped
by
ENGLISH
•
Check valve leaky.
− Have check valve serviced by
qualified service centre.
•
Pressure regulator not opened wide
enough.
− Open pressure regulator more.
•
Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.
7. Repairs
A
Danger!
Repairs to power tools must be
8. Environmental Protection
11