Phase 1
Phase 2
26
28min
Phase 3
Phase 4
27
30min
Phase 1

4.2. DOWNLOADING THE MOBILE APPLICATION

Download the MyTens app on your phone or tablet, on the Apple store or Google Play.
Or, download the BewellConnect app on your phone or tablet, on the Apple store or
bw
M y
Google Play. Then, click on the MyTens sub-app.

4.3. STARTING AND USING MYTENS / MYTENS PRO.

Check the MyTens App User Manual online before to start using the device.

5. ACCESSORIES

MyTens and MyTens pro are supplied with the following unique accessories developed for
optimal results: 
- Micro-USB cable for charging the device. 
- BewellConnect®case. 
- MyTens: One pair of electrodes.
- MyTens Pro: two pairs of electrodes.
The electrodes eventually wear out and need to be replaced. It is recommended to replace the
electrodes after about 15 to 20 uses. For purchasing information, check BewellConnect® online
store or your reseller.

6. STORAGE AND MAINTENANCE

Replace the electrodes in their protective bag and close it well to avoid dust on the electrodes.
Avoid extreme heat and exposure to direct sunlight. Do not keep the electrodes in the freezer
or the refrigerator.
50
BewellConnect - BW-TSX/BW-TS1 - User Manual - 12-2018_v2
Preparation
5Hz (5mn)
370
55Hz (10s)
370
50% Up: 1,5s
Down: 0,75s
EMS
6Hz (8s)
370
Intensity: 25%
3Hz (10mn)
370
50Hz
200
EMS

6.1. CLEANING

Warning: Never immerse the product in water and do not rinse it. Never immerse the electrodes
phase
in water. Do not use cleaning agents other than those mentioned below. They could cause
Intensity:
serious damage to the equipment.
1. Using a damp cloth and mild detergent (eg: dishwashing liquid), clean the device. It is also
possible to use isopropyl alcohol at 70° (IPA).
2. If dirt gets on the electrodes, put a drop of water on your finger and gently remove the dust
from the surface. Do not use soap or alcohol to clean the electrodes.
Phase of
relaxation

7. TROUBLESHOOTING GUIDE

Intensity:
PROBLEM
40%
The battery indicator on the
Up: 2s
device is displayed in orange
Con: 8s
continuously
Down: 2s
Rest: 4s
Orange battery light and
then the device switches off
Treatment which seems
to be different from or less
pleasant than the previous
one
Unpleasant sensation when
touching the connectors of
the device or the electrodes
The APP cann't connect to
the BW-TSX device
POSSIBLE CAUSE
Low or discharged battery
Low or discharged battery
1. Electrodes not placed in
the correct location
2. Current Intensity too low
or very high
3. Expiry date on the
electrodes exceeded
4. Worn electrodes
5. Electrodes too dirty
6. You did not correctly
apply the electrodes to the
skin
The session has not been
stopped in the application
or the on/off button has
not been pressed before
removing the device
The Bluetooth connection
failure.
BewellConnect - BW-TSX/BW-TS1 - User Manual - 12-2018_v2
SOLUTION
Recharge the device
Recharge the device
1. Switch off the device, take
off the electrodes and move
them slightly on the skin
surface.
2. In the App, modify the
intensity level.
3. Remove the electrodes
and replace them with new
ones.
4. Replace the electrodes.
5. Clean the electrodes
(paragraph 5.2 "Cleaning").
If the problem occurs again,
replace the electrodes.
6. Switch off the unit, take
off the electrodes and make
sure to place them properly
on the skin.
Always end the session in
the application or remember
to press the on/off button
before removing the device.
Restart the BW-TSX and the
APP.