TROUBLESHOOTING

Problem
Tire inflator shut-off.
Lack of power output.
Loud buzzing sound.
Inverter Power Indicator
is not lit.
Inverter automatically
shuts down.
Television/power
tool will not start.
Television Interference.
Static/noise
interference in audio
system.
18
Cause
High temperature
protection.
Battery voltage is below
10 volts.
Excessive current drawn
by appliance being
operated.
Inverter fuse blown.
Battery charge level is
too low.
Excessive voltage drop.
Inverter is overloaded.
AC overload.
Required wattage
exceeds peak surge for
start-up.
Picture breaking up
(static).
Sound system has weak
alternating current
shielding.
Solution
Allow the unit to cool for about 10 minutes.
Recharge immediately.
Reduce load to maximum wattage.
1. Turn off the device and inverter.
2. Disconnect device.
3. Turn the inverter on and let it run for a
minimum of 2 minutes.
4. Turn inverter off.
5. Quickly plug device into inverter.
6. Turn on both the inverter and the device.
Check and replace if necessary. Be sure
replacement fuse is the same type and rating.
1. Disconnect all appliances.
2. Turn inverter off.
3. Charge fully. (See charging section for
more details.)
Check internal battery status and recharge if
voltage drops below 10 volts.
Reduce load to maximum wattage.
Unplug and power off to restart then reduce AC
load to maximum wattage.
Toggle the Inverter Switch on and off in quick
succession for 5 times. If the device does not
start, the device is not compatible with this type
of inverter.
Place the unit as far as possible from the TV,
antenna, and coaxial cable.
TV station may be out of range.
Do not use the inverter with low-quality audio
AC filtering system.
Replace audio system with high quality noise
filtering.