FEATURES
Control Panel
Interior Air
Inlet
UNIT CONTROL PANEL
1. ON/OFF Button: Press to turn the unit on/off. NOTE: The unit will automatically launch the Energy Saver function
when it is in Cool, Dry and Auto modes.
2. Temperature UP/DOWN Buttons: To change the temperature setting, press or hold either the UP (
(
) button, until the desired temperature is seen on the display. This temperature will be automatically maintained
anywhere between 17°C (62°F) and 30°C (86°F). In Cooling mode, the display reads the set temperature, while in
Fan mode, the current room temperature is displayed.
3. Fan Speed Button: Select from four different fan settings: Auto, Low, Med or High. Each time the button is pressed,
the fan speed is shifted.
4. Mode Button: Allows you to scroll through and select the desired operating mode: Auto, Cool, Dry and Fan. The se-
lected mode will be denoted by the adjacent indicator light.
Operation in Auto Mode:
Auto is a pre-set factory program that automatically defi nes the mode and fan speed, based on the set temperature
you have chosen. An example of Auto operation is as follows:
If you would like to cool down your room, your desired / set temperature will be below the room temperature, and your
air conditioner will go into cooling mode. Once the room has reached your desired temperature, the air conditioner will
switch to Fan mode, and circulate the cooled air around the room. When the temperature in the room goes up, the
unit will switch back to cooling mode, and the Auto cycle will start again.
Operation in Dry Mode:
Please note that in this mode you cannot set the desired humidity level, it is automatically pre-set. The fan speed in
this setting is defaulted to "low". Since the compressor is operating in order to remove moisture from the air, you will
experience a degree of cooling as a by-product.
Operation in Fan Only Mode:
Use this function, when cooling is not desired, such as for room air circulation, or to exhaust stale air. Remember
to open the vent during this function, but keep it closed during cooling, for maximum cooling effi ciency. In this mode
you can choose any fan speed you prefer. In Fan mode, the temperature cannot be set, and the display will read the
current room temperature.
5. Energy Saver: This is the default setting on this model. The unit will automatically cycle the fan on and off while
the compressor is not in use. The fan will continue to run for 3 minutes after the compressor shuts off. The fan then
cycles on for 2 minutes at 10 minute intervals, until the room temperature is above the set temperature. At this point,
the compressor turns back on and cooling re-starts. When the unit is in Energy Saver mode, the indicator light above
the Energy Saver button will be illuminated. You can take the unit out of Energy Saver mode by pressing the Energy
Saver button - the indicator light about the button will turn off. If you choose the non-Energy Saver option, the fan will
run continuously when the compressor is not in use.