Note : The total power of the PA speakers is equal to power of the power amplifier. For example, if you have a 60W power amplifier and 15W
PA speaker, you must connect only 4 PA speakers ( 15Wx4 = 60W )
Connect the 70V output of the power amplifier + socket of the PA speaker
Connect the com socket of the power amplifier on the – socket of the PA speaker
Note : In P.A., for more operating security, you must to keep 20% of free power
On the 100V output, you can connect several PA speakers.
Note : The total power of the PA speakers is equal to power of the power amplifier. For example, if you have a 60W power amplifier and 15W
PA speaker, you must connect only 4 PA speakers ( 15Wx4 = 60W )
Connect the 100V output of the power amplifier + socket of the PA speaker
Connect the com socket of the power amplifier on the – socket of the PA speaker
Note : In P.A., for more operating security, you must to keep 20% of free power
On each zone outputs, you can connect one or severals PA speaker.
Note : The total power of the PA speakers is equal to power of the power amplifier. For example, if you have a 120W power amplifier and 15W
PA speaker, you must connect only 8 PA speakers ( 15Wx8 = 120W )
Connect the zone output of each zone of the power amplifier + socket of the PA speaker
Connect the com socket of each zone of the power amplifier on the – socket of the PA speaker
Note : In P.A., for more operating security, you must to keep 20% of free power
TECHNICAL SPECIFICATIONS :
UPB-120 USB :
Power :
Outputs :
Frequency response :
THD :
Tone ( bass / treble ) :
Phantom power :
Consumption :
Power supply :
Dimensions :
Protection :
UPB-240 USB :
Power :
Outputs :
Frequency response :
THD :
Tone ( bass / treble ) :
Phantom power :
Consumption :
Power supply :
Dimensions :
Protection :
CE, ROHS norms
WARRANTY CONDITIONS
BST PRO equipment is covered by a 2years warranty on parts and labour
The following rules apply from the day the equipment leaves the factory:
The date on the invoice is considered to be the date the warranty begins.
Only companies approved by BST PRO are allowed to work on the equipment. Warranty becomes void when other service technicians open the
equipment.
During warranty period, defective equipment must be sent by pre-paid mail in the original box.
BST PRO will return the goods by pre-paid mail during the first year of warranty; thereafter the mailing cost is to be paid by the recipient
Potentiometers have a limited lifetime and are not covered by the manufacturer for more than normal use.
For all service enquiries, refer to your local distributor, as he is best able to help you
© Copyright LOTRONIC 2018
UPA-120TU / UPA-240TU
120W
4 zones / 100V/70V/4-16 Ohms
50Hz – 20KHz
<0.5%
+/-10dB (100Hz) / +/-10dB (10KHz)
+24V
200W
110-120 / 220-240V / 50-60Hz or 24V DC
484 x 88 x 280mm ( rackable 19'' / 2U )
short circuit, overload, overheat, DC output,...
240W
4 zones / 100V/70V/4-16 Ohms
50Hz – 20KHz
<0.5%
+/-10dB (100Hz) / +/-10dB (10KHz)
+24V
200W
110-120 / 220-240V / 50-60Hz or 24V DC
484 x 88 x 280mm ( rackable 19'' / 2U )
short circuit, overload, overheat, DC output,...
Page 10