PRESIDENT ANDY II FCC Manuel D'utilisation page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

the weather channel blink on the display. The unit cancels
PA
mode and goes to
WX
During a SIREN tone sound, press any key to stop the sound, "ALERT"
and the Weather Channel stop blinking on the display.
Note: The SIREN tone sounds when an ALERT is detected in the
selected weather channel only. Use first SCAN function in
mode to detect the alerts in all the weather channel (see § CB/
WX page 8).
7) EMG ~ EMG STORE
EMG
(short press)
Emergency channels will be automatically selected by pressing
the EMG key (7). First press : emergency channel 1 is activated.
Second press: emergency channel 2 is activated. Third press: return
to the current channel. "EMG" appears on the display when an
emergency channel is activated. The default emergency channels
are channel 9 (1) and channel 19 (2).
Note: Activating an emergency channel prevents use the
§ PA page 11) mode. If the KEY BEEP function is activated, an
error beep sounds.
EMG STORE
(long press)
Emergency channel can be stored to any channel. To set a new
emergency channel:
Short press the EMG key (7) to call the current emergency channel.
-
"EMG" appears on the display.
-
Long press the EMG/STORE key (7).
"EMG" blinks.
-
Using the s/t keys (3), select the new emergency channel.
-
Short press the PTT switch (11) to validate and store the new emer-
gency channel. A validation beep sounds.
Note: Emergency setting is not allowed if the active channel is not
an emergency channel.
8) VOX ~ VOX SET
VOX
(short press)
mode.
appears on the display and
CB
The VOX function allows transmitting by speaking into the original
or
microphone (or in the optional vox microphone) without pressing
the PTT switch (11). The use of an optional vox microphone con-
nected to the rear panel of the transceiver (E) disables the original
microphone.
Press shortly the VOX key (8) in order to activate the VOX function.
WX
«VOX» appears on the display. A new press on the VOX (8) key
disables the function, «VOX» disappears.
VOX SET
(long press)
1. Long press the VOX/SET key (8) to enter the VOX SETTING. "VOX"
blinks, the current setting and its value appear on the display.
Three parameters allow to adjust the VOX: Sensitivity: L / Anti-vox
level: A / Vox delay time: t.
2a. Use the s/t key (3) to modify the current parameter then, press
the NB key (5) to select the next parameter or....
2b. Press first the NB key (5) to select another parameter and then use
the s/t key (3) to modify the current parameter.
3. When all adjustments are done, press the PTT switch (11) to store
PA
(see
and exit. If the KEY BEEP function is activated, a long beep sounds
to confirm the success of the operation (see § KEY BEEP page
10).
4. If no key is pressed for 10 seconds, the unit automatically exits the
function VOX SETTING without saving.
-
Sensitivity L: allows the adjustment of the microphone (original one
or optional vox) for an optimum transmission quality. Adjustable
level from L1 (high level) to L9 (low level). Default value: L5.
-
Anti-Vox A: allows disabling the transmission generated by the
surrounding noise. The level is adjustable. AF (according the
squelch level) and from A0 (without anti-vox) to A9 (low level).
Default value: AF.
-
Delay time t: allows avoiding the sudden cut of the transmission
by adding a delay at the end of speaking. The level is adjustable
from t1 (short delay) to t9 (long delay). Default value: t1.
VOX SETTING doesn't activate the VOX function.
9

Publicité

Table des Matières
loading

Table des Matières