Assembling
Permissible stresses
To avoid damage to the cylinder, don't apply loads to the external structure.
Radial loads or torque force to the rod: see admitted values on catalogue.
See admitted values
on catalogue
Magnetic limit switches
Magnetic sensors: Any collision of the piston at the end of stroke can damage the electric
cylinder. Therefore it is advisable to use a magnetic sensor at the end of the stroke
(avoid bodies magnetic/ferrous near the switches).
Both REED and HALL effect switches can
be used. For both versions and ordering
codes available, see catalogue.
The switches must be attached to the
barrel using the specified aluminium
brackets. For the ordering codes see the
image on the right side.
How to assemble the switches (see image below):
• remove the screw as shown on pos.1 and attached to the bracket as shown in pos.2
• attach the switch/bracket on to the barrel in the required position and fix with the screw as
shown on pos.3.
There after, check that the function of the switch is correct and is in the correct position by
operating the actuator slowly. This will help avoid damage to the cylinder because of incor-
rect switch position. The Homing search phase must be performed at low speed
(close to 10mm/sec) to avoid harmful impacts to the device.
Screw pos. 2
Grain pos.1
For the types of sensors that can be used
refer to the catalogue.
Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice
See admitted values
Grain pos. 3
Electric cylinders
Series 1800
on catalogue
Sensor brackets
1580._, MRS._, MHS._
Code
1320.AS
1320.BS
Size
L1
32
48
40
54
50
66
63
76
21