Voici une copie de l'étiquette apposée sur chaque
poêle à bois autoportant Hampton H300 afin de
vous permettre d'en examiner le contenu.
COPIE DE L'ÉTIQUETTE DE SÉCURITÉ - MODÈLE H300
LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO
SUITABLE FOR MOBILE HOME INSTALLATION
APPAREIL DE CHAUFFAGE AMBIANT HOMOLOGUÉ
À COMBUSTIBLE SOLIDE, CONVENANT AUSSI
POUR INSTALLATION DANS UNE MAISON MOBILE
MODEL: HAMPTON CAST FREESTANDING WOOD STOVE - H300
MODÈLE : POÊLE À BOIS AUTOPORTANT EN FONTE HAMPTON - H300
TESTED TO: UL-1482, ULC-S627-00
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT
FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING
A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
INSTALLER ET UTILISER SEULEMENT SELON LES CONSIGNES D'INSTALLATION ET D'UTILISATION DU FABRICANT.
CONTACTER LES RESPONSABLES DU BÂTIMENT OU DU SERVICE-INCENDIE DE VOTRE RÉGION POUR CONNAÎTRE LES
RESTRICTIONS ET EXIGENCES D'INSPECTION DANS VOTRE RÉGION. UTILISER UN CONNECTEUR D'UN DIAMÈTRE MINIMAL
DE 150 MM (6 PO) 24 MSG EN ACIER NOIR OU 26 MSG EN ACIER BRONZÉ AVEC CHEMINÉE PRÉFABRIQUÉE HOMOLOGUÉE
UL103 HT CONÇUE POUR UTILISATION AVEC COMBUSTIBLES SOLIDES OU UNE CHEMINÉE DE MAÇONNERIE.
VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT CONCERNANT LES PRÉCAUTIONS EXIGÉES
POUR INSTALLER UNE CHEMINÉE TRAVERSANT UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES. NE PAS FAIRE
TRAVERSER LE CONNECTEUR DE CHEMINÉE DANS UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES. NE PAS
RACCORDER CE POÊLE À BOIS À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.
MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS
MEASURE
FLUE
FROM
HEATER
CENTER-LINE
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
SIDEWALL
A 431 mm / 17 in
D 762 mm / 30 in
BACKWALL B 381 mm / 15 in
E 381 mm / 15 in
CORNER
C 330 mm / 13 in
F 483 mm / 19 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
SIDEWALL
A 381 mm / 15 in
D 711 mm / 28 in
BACKWALL B 254 mm / 10 in
E 254 mm / 10 in
CORNER
C 228 mm / 9 in
F 381 mm / 15 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
SIDEWALL
A 381 mm / 15 in
D 711 mm / 28 in
BACKWALL B 254 mm / 10 in
E 254 mm / 10 in
CORNER
C 228 mm / 9 in
F 381 mm / 15 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
SIDEWALL
G 381 mm / 15 in
I 711 mm / 28 in
BACKWALL H 330 mm / 13 in
J 330 mm / 13 in
* In Canada, fl oor protection must extend 18"
(457mm) to the front and 8" (200mm) to each
side and back of the stove.
IF SIDE LOAD DOOR IS USED:
Floor protection must extend 18" (457mm) from the side of the
unit to the wall.
Floor protection must be a minimum of 3/8" thick with a mini-
mum k factor of 0.84.
Minimum clearance with side load door in use is 18" (457mm)
to side wall or refer to dimension (A) if side load door is not
used.
MANUFACTURED BY / FABRIQUÉ PAR :
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4
MADE IN CANADA / FABRIQUÉ AU CANADA
Part #: 918-216d
Size:
7.489" H x 10.47" W (File at 100%)
Color:
Black on grey except what is indicated is printed red on grey.
Jan. 31/08: added short leg option.
Mar. 1/10: updated logo
Jan. 21/13: Updated date of manufacture
Jan. 30/14: Rev. C - Added French copy
May 06/15: Updated yrs. of manufacture/removed 1990 EPA info
Apr 29/16: Rev. D - Updated yrs. of manufacture 2017-2021
REMARQUE : Nous améliorons constamment
lles appareils Hampton. Comparez cette copie
avec l'étiquette apposée sur votre appareil. S'il
existe une différence, fiez-vous à cette dernière.
254
DO NOT REMOVE THIS LABEL
NE PAS RETIRER CETTE ÉTIQUETTE
254
REPORT NO: 219-S-04-2
DO NOT PASS CHIMNEY CONNECTOR THROUGH
DÉGAGEMENTS MINIMAUX DES
MATÉRIAUX COMBUSTIBLES
MESURES
À PARTIR
DU POÊLE
CONDUIT DE CHEMINÉE
INSTALLATION RÉSIDENTIELLE UTILISANT
UN CONNECTEUR À SIMPLE PAROI
MUR LATÉRAL
A 431mm/17po
MUR ARRIÈRE
B 381mm/15po
COIN
C
330mm/13po
INSTALLATION UTILISANT UN CONNECTEUR
HOMOLOGUÉ À DOUBLE PAROI - MAISON MOBILE
MUR LATÉRAL
A 381mm/15po
MUR ARRIÈRE
B 254mm/10po
COIN
C
228mm/9po
INSTALLATION UTILISANT UN CONNECTEUR HOMOLOGUÉ
À DOUBLE PAROI - RÉSIDENTIELLE (DÉGAGEMENT
RÉDUIT)
MUR LATÉRAL
A 381mm/15po
B 254mm/10po
MUR ARRIÈRE
C
COIN
228mm/9po
INSTALLATION UTILISANT UN CONNECTEUR
HOMOLOGUÉ À DOUBLE PAROI - ALCÔVE
G 381mm/15po
MUR LATÉRAL
FLOOR
H 330mm/13po
MUR ARRIÈRE
PROTECTION*/ PROTEC-
TION DE PLANCHER*
*
Au Canada, la protection de plancher doit dépasser de
K 457 mm / 18 in
18 po (457 mm) à l'avant et de 8 po (203 mm) de chaque
L 150 mm / 6 in
côté du poêle et derrière le poêle.
M 150 mm / 6 in
SI LA PORTE DE CHARGEMENT LATÉRALE EST UTILISÉE :
Une protection de plancher doit dépasser de 18 po (457 mm) du côté
de l'appareil au mur.
Une protection de plancher doit avoir une épaisseur d'au moins 3/8 po
avec un facteur de 0,84k minimum.
Si la porte de chargement latérale est utilisée, le dégagement minimum
est de 18 po (457 mm) à la paroi latérale ou se reporter à la cote (A) si
la porte de chargement latérale n'est pas utilisée.
MINIMUM ALCOVE CEILING HEIGHT: 1.5 M / 5 FT
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 457 MM / 18"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.
FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION.
DO NOT OBSTRUCT COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH DOOR
CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON
HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN
CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY.
KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM
GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER
AND TO THE FRONT AND SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN (846-515), ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, SHORT LEGS (200-931, 200-935)
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER
OR IN FRONT OF APPLIANCE.
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL
CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED
CHIMNEY SYSTEM: SECURITY MODEL S2100, ICC EXCEL 2100.
IN USA: LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV,
SIMPSON DURA VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING
COMPATIBLE CHIMNEY SYSTEMS SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET
3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL-FAB TEMP/GUARD, AMERI-TECHS, ICC EXCEL 2100 . USE CHIMNEY
COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.
HAUTEUR MINIMALE DU PLAFOND DE L'ALCÔVE : 1,5 M / 5 PI.
DÉGAGEMENT MINIMAL DU PLAFOND POUR UN CONNECTEUR HORIZONTAL : 457 MM / 18 PO.
L'ESPACE AU-DESSOUS DU POÊLE NE DOIT PAS ÊTRE OBSTRUÉ. UTILISER SEULEMENT AVEC LES BRIQUES RÉFRACTAIRES
EN PLACE.
POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. L'UTILISATION D'AUTRES COMBUSTIBLES PEUT ENDOMMAGER LE
POÊLE ET S'AVÉRER DANGEREUSE . NE PAS OBSTRUER LES OUVERTURES D'AIR DE COMBUSTION. UTILISER SEULEMENT
AVEC LA PORTE FERMÉE – OUVRIR LA PORTE DE CHARGEMENT SEULEMENT POUR ALIMENTER LE FEU. NE PAS UTILISER
DE GRILLE À BÛCHES NI SURÉLEVER LE FEU. MONTER LE FEU DE BOIS DIRECTEMENT SUR L'ÂTRE. NE PAS SURCHAUFFER
– SI LE POÊLE OU LE CONNECTEUR DE CHEMINÉE SE MET À ROUGIR, C'EST LE SIGNE D'UNE SURCHAUFFE . INSPECTER ET
NETTOYER FRÉQUEMMENT LA CHEMINÉE ET LE CONNECTEUR. DANS CERTAINES CONDITIONS D'UTILISATION, UN DÉPÔT
DU CENTRE DU
DE CRÉOSOTE PEUT SE FORMER RAPIDEMENT. TENIR LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES ÉLOIGNÉS
DU POÊLE. REMPLACER LA VITRE SEULEMENT PAR DU VERRE EN NEOCERAM. LE PLANCHER COMBUSTIBLE DOIT ÊTRE
PROTÉGÉ PAR DES MATÉRIAUX NON COMBUSTIBLES DÉPASSANT DU DESSOUS, DU DEVANT ET DES CÔTÉS DU POÊLE, TEL
QU'INDIQUÉ, OU JUSQU'AU MATÉRIAU COMBUSTIBLE LE PLUS PROCHE PERMIS.
D 762mm/30po
COMPOSANTS EN OPTION : VENTILATEUR (846-515), ALIMENTATION ÉLECTRIQUE : 115 VOLTS, 60 HZ, 2 AMP.
E 381mm/15po
DANGER : RISQUE D'ÉLECTROCUTION. DÉCONNECTER L'ALIMENTATION ÉLECTRIQUE AVANT DE FAIRE L'ENTRETIEN DU
F
483mm/19po
POÊLE. NE PAS INSTALLER LE CORDON ÉLECTRIQUE SOUS OU DEVANT L'APPAREIL.
COMPOSANTS EXIGÉS POUR L'INSTALLATION DANS UNE MAISON MOBILE : KIT DE PRISE D'AIR EXTÉRIEUR ET UN DES
CONNECTEURS DE CHEMINÉE À DOUBLE PAROI SUIVANTS :
D 711mm/28po
AU CANADA : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, OU OLIVER MA-
E 254mm/10po
CLEOD PRO-VENT PV, AVEC SYSTÈME DE CHEMINÉE HOMOLOGUÉ : SECURITY MODÈLE S2100, ICC EXCEL 2100.
F
381mm/15po
AUX ÉTATS-UNIS : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, SELKIRK MODEL
DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODÈLE DVL, GSW SUPER PIPE 6, METAL-FAB À DOUBLE PAROI.
CONNECTÉ À L'UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS : SECURITY MODÈLE S2100 OU MODÈLE ASHT,
SELKIRK MODÈLE SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODÈLE SC OU METAL-FAB TEMP/
GUARD, AMERI-TECHS, ICC EXCEL 2100. UTILISER LES COMPOSANTS DE CHEMINÉE SPÉCIFIÉS DANS LES INSTRUCTIONS
D 711mm/28po
E 254mm/10po
D'INSTALLATION.
F
381mm/15po
I 711mm/28po
J 330mm/13po
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
SURFACES CHAUDES DURANT LE FONCTIONNEMENT.
NE PAS TOUCHER. TENIR LES ENFANTS, LES VÊTEMENTS
TOUT CONTACT PEUT CAUSER DES BRÛLURES. LIRE LA
918-216d
Poêle à bois autoportant en fonte Hampton® H200 / H300 |
étiquette de sécurité
MAXIMUM ALCOVE DEPTH 1220 MM / 48 IN.
PROFONDEUR MAX. DE L'ALCÔVE : 1220 MM / 48 PO.
CAUTION
ATTENTION
ET LES MEUBLES ÉLOIGNÉS DE L'APPAREIL.
PLAQUE SIGNALÉTIQUE ET LES INSTRUCTIONS.