Jandy Heat Pump Models EE-Ti Installation and Maintenance Manual
pressing the Up or Down button . Repeatedly press
the Up or Down button until you reach the desired
temperature set point. After 5 seconds of inactivity, the
new set point is stored in memory.
When the water temperature falls to 1 degree
below the temperature setting
delay, the control will start the heat pump and the
associated right LED will light RED
5.2.3
Pool Mode - (Optional Maintain
Heat)
If connected, the Maintain Heat mode allows the
heat pump to monitor the temperature of the water 24
hours a day by turning the pool pump on and sampling
the water temperature.
A Maintain Temp Relay is required (provided) and
the feature must be enabled.
When the water temperature drops below the
programmed temperature set point, the control will start
the heat pump.
To operate in pool mode with the Maintain
Heat feature, press POOL , then press MENU, press
the Down button until MAINTAIN POOL HEAT is
displayed, press the MENU button.
The associated left green LED indicator will
light and the unit will display SET:XXX°. Change the
temperature set point by pressing the Up or Down
button until the desired set point is displayed. After
5 seconds of inactivity, the new set point is stored in
memory.
5.2.4

Spa Mode - (Normal Heat)

To enable the spa mode, press SPA . The
associated left green LED indicator will light and the
unit will display SET:XXX° .
XXX
NOTE
represents the current temperature setting
on the control. The default setting for spa
temperature is 102°F (38°C).
You can change the temperature set point by
pressing the Up or Down button . Repeatedly press
the Up or Down button until you reach the desired
temperature set point. After 5 seconds of inactivity,
the new set point is stored in memory. When the water

Figure 15. Main Control Panel

and
after a 5 minute
.
temperature falls to 1 degree below the temperature
and
setting
after a 5 minute delay, the control will start
the heat pump and the associated right LED will light
RED.
5.2.5

Spa Mode - (Optional Maintain Heat)

If connected, the Maintain Heat mode allows the
heat pump to monitor the temperature of the water 24
hours a day by turning the spa pump on and sampling
the water temperature.
A Maintain Temp Relay is required (provided) and
the feature must be enabled.
To operate in spa mode with the Maintain Heat
feature, press SPA , then press MENU, press the Down
button until MAINTAIN SPA HEAT is displayed, press
the MENU button. The associated left green LED
indicator will light and the unit will display SET:XXX°.
Change the temperature set point by pressing the Up
or Down button until the desired set point is displayed.
After 5 seconds of inactivity, the new set point is stored
in memory.
5.3
Operating Features of Hybrid Units
with Optional Chiller
The chiller is an optional equipment. Not all
NOTE
units are provided with chiller
5.3.1

Pool Mode - (Normal Chill)

To enable the pool mode, press POOL . The
associated left green LED indicator will light and the
unit will display SET:XXX° .
XXX
NOTE
represents the current temperature setting
on the control. The default setting for pool
temperature is 80°F (26°C).
Press the MENU button. P ress the Up or Down
button until you reach POOL CHILL , press the MENU
button.
NOTE POOL CHILL will not be displayed if the unit is
not provided with chiller.
You can change the temperature set point by
pressing the Up or Down button . Repeatedly press
the Up or Down button until you reach the desired
temperature set point. After 5 seconds of inactivity,
the new set point is stored in memory. When the water
temperature rises to 1 degree above the temperature
and
setting
after a 5 minute delay, the control will start
the heat pump and the associated right LED will light
GREEN
.
5.3.2
Pool Mode - (Optional Maintain
Chill)
If connected, the Maintain Chill option mode
allows the unit to monitor the temperature of the
water 24 hours a day by turning the pool pump on and
sampling the water temperature.
.