effegibi H-Large Manuel D'utilisation Et D'entretien page 50

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
H LARGE / H MEDIUM / H SMALL OPERATING AND MAINTENANCE MANUAL
TROUBLE-SHOOTING
Please note: the information in the table below and the action to take is intended for the use
of the assistance centre personnel and others qualified to install/maintain the equipment.
Error message
Critical errors
Non-critical errors
For any situations not covered in this table, consult your approved assistance centre or contact the company
direct.
48
The data and features referred to are not binding on EFFEGIBI and the company reserves the right to make any appropriate changes without having to give prior warning or
Meaning
No software dia-
Lack of
logue with an ele-
communication
ment already reco-
with 1 or more
gnised.
devices.
The control panel is
Lack of
not in dialogue with
communication
the other electronic
with 1 or more
elements.
devices.
New
peripheral
device recognised.
Boiler full too soon. The boiler filled
too quickly during
initial rinsing or final
emptying.
Boiler not yet full.
The boiler didn't
fill within the
prescribed time
limit during initial
rinsing or final
emptying.
Boiler not yet
The water level in
empty.
the boiler remained
too high for too
long during initial
rinsing or final emp-
tying.
replace this manual.
Error
Cause
One of the devices
is
not
receiving
power or is not
connected.
One of the devices
is not receiving po-
wer or is not con-
nected.
A new component
has
connected to the
product.
Outlet valve not
working.
Lack of water in
the system or the
inlet valve filter is
blocked.
Outlet
valve
working.
Solution
1. Check the devi-
ce connections.
2. Run the start-up
sequence.
1. Check the devi-
ce connections.
2. Run the start-up
sequence.
1.
Check
been
connections
and
power cabling.
2. Run the start-up
sequence.
1. Check that the
outlet path is clear.
2. Check that the
steam pipe is not
obstructed, bent or
is not siphoning.
3. Clean the outlet
valve.
1. Check that the
water tap is turned
on.
2. Check that there
is water in the
system.
3. Check that
the filter at the
entrance to the
inlet valve is not
blocked.
not
1. Check that the
outlet path is clear.
2. Check that the
steam pipe is not
obstructed, bent or
is not siphoning.
3. Clean the outlet
valve.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

H-mediumH-small

Table des Matières