Télécharger Imprimer la page

Enraf Nonius EN-Tree Bench Mode D'emploi page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Absolute contra-indicaties:
Myocardiac dysfunction in an instable phase
HNP in the (sub) acute phase (with irradiation
and neurological signs)
Severe osteoporosis
Acute fractures
Severe mechanical instability
Early post-surgical joint modification
Relative contra-indications:
Myocardial disfunction in a stable phase
HNP in the sub-acute phase (with irradiation and
neurological signs)
Mild osteoporosis
Late post-surgical joint modification
Tumours
Inflammations in the involved area
Non desired articular load in the involved area
(p.e.. with M. Osgood-Schlatter, bursites, etc.)
Non desired ligamentous load in the involved
area (p.e. sprain with hydrops)
Non desired soft tissue load in the involved area
(p.e. with severe atrophy)
Cardiovascular restrictions
Pulmonary restrictions
Psychological restriction
Pain of such cause that movement would not
relief
• Both the steel undercarriage and the covering can
be cleaned with a damp cloth and a (non abrasive)
liquid household cleaner.
• If, after some time, the turning parts start
creaking,
you can re-grease them with a drop of oil.
• Check the functionning of the adjustment and grip
mechanisms at least once every six months. In
case of a deficiency, use of the EN-Tree Bench
is not recommended until the deficiency has been
corrected/repaired.
• Make sure that the chrome fixation bar and the
chrome plate are always degreased, in order to
guarantee a good grip.
• In order to obtain spare parts, you can contact
your supplier.
6
CONTRA-INDICATIONS
MAINTENANCE
We hope that you will use the EN-Tree Bench for
a long time with much satisfaction and we take the
liberty of drawing your attention to the many other
high quality products in our programme. If you should
have any questions or wish to receive our catalogue,
please contact our representative.
Dimensions
(height x width x depth):
Weight:
Maximum load per section
in its lowest position
Angle adjustment
- back section:
- leg section:
Technical modifications reserved
ENVIRONMENT CONDITIONS FOR
TRANSPORT AND STORAGE
Environment temperature: between -40 and
+70°C
Relative humidity:
Atmospheric pressure:
hPa
EN-Tree Bench
Operating instructions
Publication "Medical Training Therapy
with the EN-Tree (English)
This design is registered
1)
FINALLY
TECHNICAL DATA
48 x 47 x 134 cm
25 kg
135 kg
0° to 75°
0° and 7°
between 10 and 100%
between 500 and 1060
ORDERING DATA
3443.356
3443.358
1400.799

Publicité