NATURAL GAS CONVERSION
26. Remove the old orifice using the orifice
removal tool. Tighten the new orifice.
26.1Unscrew the pre-assembled screw as
shown, rotate the air shutter opening
clockwise, adjusting it from the LPG
setting to the NG setting. Replace the
pre-assembled screw, thus securing the
air shutter opening.
φ1.30mm Orifice
Orifice removal tool
27. Reinstall the Shelf Tray, Burner, Ingnition
Wire and Rack.
27.1 Use the M19 Wrench (not included) to
remove the LP hose and regulator from
the manifold. Attach the Natural Gas
Hose (sold separately) and tighten it with
the wrench.
28. Remove the 5 knobs for the main burners
and side burner by grasping and pulling
out.
Insert the slotted screwdriver into the hole of
each control valve shaft as shown. Rotate
the shaft counterclockwise (to the left) as
far as it will go (about 2 complete turns)
until it stops. The shaft will now be set in
the NG position.
Re-attach the control knobs. Paste the new
rating label for NG near the original LP
rating label on the bottom panel.
NG conversion is now completed.
Leak Check
When checking for gas leaks, do not use an open flame. Use a soapy water solution and apply it
to the pipe joints and fittings with a brush and check for bubbles. Check flexible hoses for cuts
and wear that may affect the safe operation of the grill. Only use original equipment replacement
hoses. Use only replacement hose assemblies specified by manufacturer.
x1
x1
20
26
27
28
1
2