INSTALLATION MANUAL
SOLARKPW-SOLARKPB
Dual Technology Digicode
1] PRODUCT PRESENTATION
Dual technology: Proximity reader and/
or Digicode
keypad.
®
Wiegand 26, 30 or 44 bit.
Sensitive touch keypad.
PCB sealed in epoxy.
Audible and visual feedback.
Version available in: white or black.
WEEE
2] REMINDERS AND RECOMMENDATIONS
Operating mode
SYSTEME
KEYPAD
PROXIMITY
TELACCESS
4
TERENA
4
CENTAUR
4
ATRIUM
4
Cable
- Programming your installation before installing
products on site.
- The distance between a CENTAUR and ATRIUM
controllers or an INTBUSW reader interface
should not exceed more than 50 meters.
- Make sure that the cable is not near by a high
voltage cables (ex: 230 V AC).
- Recommended cable 2 twisted pairs
SYT1 0.8MM (AWG 20).
3] MOUNTING KIT
Foam seal
SOLARKP RANGE
2
cdvigroup.com
/Proximity reader - Wiegand
®
IP53
MODE
DUAL TECHNOLOGY
4
4
-
4
4
4
-
4
3x30
TF screw
1
2
Technology: 125 Khz.
Multi card protocol reader - Marin/HD.
Input voltage: 12V dc.
Consumption: 150mA.
Certification FCC CFR 47
part 15 compliance
Back EMF protection
To secure the system from back electromagnetic
fields do not forget to mount the varistor in parallel
on the lock terminals.
Security Advice
- For security reasons, change the factory default
master code.
- When selecting a master code and user code
avoid simple codes (example : 3 4 5 6 7).
Mounting recommendations
Mount the keypad on a flat surface to avoid
any vandalism and to insure the best mounting.
Recommended power supplies
ARD12 & BS60. These products must be powered
in 12Vdc and the power supply should be
certified EN60950-1:2006/A11:2009 standards
and should be designed to be a low power supply
source.
S5
TORX
Plastic anchor
2
-25°C to +70°C
3x8
bit
®
TORX
screw
®
1
1
EN
CE Certification

Publicité