1.7 Cable specification
Type
PVC-UL
Y-UL 2517
Silicone
SiHSI *
Silicone
SXCS
shielded *
PUR
BOY11Y **
PVC gray
Boflex-W
PVC gray
LIYCY W
shielded
PUR silicone free, UL
HK-SO-Li9Y11Y-OZ-
HF
* The cable is halogen-free.
** The cable coating is halogen-free.
 Follow the applicable installation advice when installing the
cables.
 At ambient temperatures lower than -5 °C, ensure the cables
are properly supported.
Note The sensors are double insulated, therefore no protective
conductor is necessary.
Date: 20.04.2016
Operating
temperature
-30 °C ... 105 °C 300 Volt 100 pF/m
-25 °C ... 180 °C 400 Volt 60 pF/m
-25 °C ... 180 °C 400 Volt 60 pF/m
-40 °C ... 85 °C
-40 °C ... 105 °C 300 Volt 115 pF/m
-40 °C ... 105 °C 250 Volt 100 pF/m
-40 °C ... 85 °C
Voltage
Capacitance/
rating
inductance
0.7 H/m
1 nH/m
1 nH/m
250 Volt 100 pF/m
1 nH/m
1 nH/m
1 nH/m
300 Volt 70 pF/m
GB