1.3 Electrical specification (sensors operated
in intrinsically safe mode)
Sensor 671 *** I** **-**, 671 *** K** **-** (with potential
terminal)
Type
Voltage rating U
( V AC/DC)
i
Current rating I
(mA), static
i
Power P
(mW)
i
Temperature class /
max. ambient temperature
1G; 1/2G ; 2G
max. ambient temperature
1D; 2D
Protection class
* -25 °C ... 75 °C T5 / II 2D / II 1D
(ANSI/UL 508/CSA C22.2#14-10)
 Ensure that the sum of all component currents does not
exceed the given current rating of the sensor.
 Ensure that the maximum rated current per switching contact
does not exceed 75 mA.
Effective internal capacitance and inductance
Cable length
Effective internal
capacitance C
i
Effective internal
inductance L
i
Date: 20.04.2016
24
60
500
T5 / 85 °C*
T6 / 70 °C
85 °C*
IP 68 10 bar (IEC 529)
10 m
50 m
2 nF
7 nF
10 H
50 H
671 *** I** **-**
671 *** K** **-**
150
500
T5 / 70 °C
T6 / 50 °C
70 °C
100 m
12 nF
24 nF
100 H
200 H
GB
200 m
36/135