11.2 If the output is not right
Fault
Little osmosis water and little
residual water
Little osmosis water but lots of
residual water
Lots of osmosis water but little
residual water
12 Technical data
Maximum daily output* (rated output):
Retention rate:
Membrane:
* Note:
The daily output of osmosis water and the ratio of osmosis water to residual water depend on the temperature of the
tap water and the pressure in the house water pipe. The higher the temperature (max. 25 °C) and the higher the
pressure (max. 6 bar), the higher the daily output and the better the flushing ratio (more osmosis water, less residual
water).
Cause
Fine filter is blocked
Hoses are bent
Water pressure in the house water
mains is too low
Flushing valve open
The membrane is blocked
Tap water is very cold (winter)
Flow restrictor is blocked or the
residual water hose is blocked
Osmose Compact 130: 130 L/day
Osmose Professional 190: 190 L/day
Osmose Professional 380: 380 L/day
Respectively at 25 °C water temperature and 4.1 bar
pressure
At least 95 % (at a pressure of at least 3 bar after 48
hours in operation)
Modern TFC dry membrane made out of polyamide/poly-
sulphone. High resistance to bacterial decomposition
Remedy
Check fine filter and replace if
necessary (see section 9)
Replace hoses
Check water pressure and if necessa-
ry the pressure (at least 3 bar)
Close flushing valve
Rinse membrane for 15 minutes
(see section 7), replace if necessary
take measures to increase
---
Replace
21