Fitting procedure
Tighten up the screw for securing unit , which was secured loosely in section 4, until it will go no further.
Note
• Tightening up the screw for securing unit too much may cause the bracket to be bent out of shape.
Lift the plasma display slightly, and check that it is firmly secured in place.
Horizontal installation
Screw for securing unit (long)
(Tightening torque: 2.5 to 3.5 N•m)
Removing the plasma display
Place a soft blanket or piece of cloth underneath the plasma display.
Remove the screw for securing unit which is attached to the side of
the wall-hanging bracket.
Horizontal installation Left or right side of wall-hanging bracket
Vertical installation Left side of wall-hanging bracket
Note
• Otherwise, the screw for securing unit may drop down by mistake,
leaving marks on the surface of the floor.
Disconnect the power cord and the wires connecting the plasma
display to the other units.
While lifting the bottom part of the plasma display, pull the plasma
display toward you.
After the bottom insulation spacers have been removed, continue
lifting up the plasma display and remove it.
Note
• The plasma display needs to be lifted up approximately 4 cm
(1.6 inches) to be removed.
16
Screw for securing unit (short)
(Tightening torque: 1.2 to 1.5 N•m)
Vertical installation
Lower
insulation
spacer
Blanket or
piece of cloth
Screw for securing
unit