English
SUbNET MaSK SETUP ScREEN
To Ping an IP address in a subnet different than the subnet of the Pinger Plus,
requires that the Subnet Mask be entered and "ON" and the appropriate Gateway
IP address has been entered. Mask "ON" and OFF" is selected with the Up/Down
Cursor key. A zero in the first field is an invalid mask entry and the Pinger defaults
to 255 when the mask is saved. NOTE: Subnet Mask and Default Gateway IP
address may be found by going to a computer on the subnet where the Pinger
Plus will be used, open the Windows Control Panel, open the network icon, open
the LAN icon, select TCP/IP Protocol and then select properties.
GaTEWaY SETUP ScREEN
The IP address for the default Gateway (typically a router or a server) is input
from this screen.
PINGER Mac ScREEN
The Pinger Plus MAC address is displayed in this screen. The MAC for each
Pinger is unique and can not be changed. See Note in DHCP.
PROFIlE SETUP ScREEN
A profile consists of a Profile name, Pinger Plus IP address, Subnet Mask on
or off, Subnet Mask, Gateway Address and a list of one to eight destination IP
addresses. One of the eight Profiles is selected using the Up/Down cursor, the
Profile name and Pinger Plus IP address is entered and the Next function key is
pressed. The Subnet Mask is entered and turned on or off and the Next fuction key
is pressed. The Gateway address is entered and the Next function key is pressed.
From one to eight destination IP addresses are entered and then the Save function
key is pressed.
DEFaUlT PROFIlE ScREEN
A default profile can be designated to be used initially when the Pinger Plus is
powered on.
POWER DOWN SETUP ScREEN
The Pinger Plus will automatically turn off after the time selected in the Power
Down Setup screen. Settings available are five minutes, fifteen minutes, thirty
minutes and on (must be turned off manually). Press the SAVE function key to store
the selected setting.
PaSSWORD ScREEN
A password is required to configure the Pinger Plus from a web browser or
update the firmware. The password protects against a third party making unauthor-
ized changes to the unit when it is connected to a network. The default password is
12345678. It is recommended that the default password be changed prior to initial
operation.
8
English
PING cOUNT SETUP ScREEN
The Pinger Plus can be set to PING an IP address from 1 to 99 times or continu-
ously. Pressing the Up/Down cursor key scrolls the number of times to PING from 1
to 99. The Continuous PING setting is shown by scrolling down from "1" or up from
"99". Multiple PINGs are not available for Lists, Profiles or Ranges.
PING PacKET SIZE aND TIMEOUT SETUP ScREENS
The PING packet size has six settings from 50 to 1400 bytes. The time
the Pinger Plus waits for a PING or DHCP response before displaying a No
Response notice can be set from 1 to 40 seconds in one second increments.
lINK SEaRcH ScREEN
The Link Search setup screen is used to set the length of time that the Pinger
Plus will monitor a wire pair for Link signals. Normal (about 2.5 seconds) is the
default setting or use the Up/Down cursor key to select the Long setting (about 5
seconds). Some switches, especially if configured for VoIP, require a longer time
to complete Link negotiations and the Long setting will provide more consistent
Link detection.
UPDaTE PINGER ScREEN
The Pinger Plus firmware can be updated over the network as new revisions
are released. Notice of a new revision will be provided on the Psiber web site
(www.psiber.com). Download the new firmware file, connect the Pinger Plus to the
network, go to the Update Pinger Setup screen, press the Select function key and
the unit will Link to the network and enable the firmware update mode. Next run the
downloaded file on the computer. The program will ask for the current IP address
of the Pinger Plus (see Pinger IP Address Setup screen) and your password.
When the update is complete the program will notify the user and the Pinger Plus
immediately goes to the Link screen and searches for the Link.
WARNING: Any disruption while programming is in process will result in the unit
being unuseable and will have to be returned to the factory for repair. Install a fresh
set of batteries or connect the AC adapter to the unit before starting an update.
POWER
–
Duration
The Pinger Plus will typically provide about 5 to 6 hours of operation
from a set of four AA alkaline batteries. An AC adapter is also provided which will
power the unit but does not recharge the batteries.
–
Auto Power Down
The Pinger will automatically turn off after the time selected
in the Power Down Setup screen or will run continuously until manually turned off
when "ON" is selected for Power Down.
–
Low Battery
When the batteries are below the level required for the Pinger
Plus to operate properly, a battery graphic appears in the upper right hand corner
of the display.
9