If the tool does not actuate properly, disconnect
the air hose, and then reassemble the trigger
according to 1-4 shown above.
NOTE:
To set back to continuous nailing, follow the procedures
for changing the trigger above.
OPERATION
CAUTION:
Make sure all safety systems are in working order
•
before operation.
When not operating the tool, always lock the trigger
•
by turning the change lever to the LOCK position.
Make sure that the trigger is locked when the
•
change lever is set to the LOCK position.
Checking continuous nailing mode
−
The tool must not operate only by connecting the
air hose.
1
2
013440
−
The tool must not operate only by pulling the trigger.
1
2
013503
−
The tool must not operate only by placing the
contact element against the work piece without
pulling the trigger.
1
2
013489
1. Trigger
2. Contact
element
1. Trigger
2. Contact element
3. Workpiece
3
1. Trigger
2. Contact
element
3. Workpiece
3
−
The tool should operate properly when pulling the
trigger first and then place the contact element
against the work piece.
Checking intermittent nailing mode
−
The tool must not operate only by connecting the
air hose.
−
The tool must not operate only by pulling the
trigger.
−
The tool must not operate only by placing the
contact element against the work piece without
pulling the trigger.
NOTE:
The operating conditions shown above are the
•
same as the operating conditions mentioned in
"checking continuous nailing mode".
1
2
013441
−
The tool must not operate when pulling the trigger
first and then placing the contact element against
the work piece.
Nailing method
1
2
013537
1.
To drive a nail, you may pull the trigger first and
then place the contact element against the
workpiece, or
2
1
013538
7
1. Trigger
2. Contact
element
3. Workpiece
3
1. Pull the trigger
2. Place the
contact element
against
workpiece.
1. Place first the
contact element
against
workpiece.
2. Pull the trigger