ELECTRIC CONNECTIONS
• Before connecting power supply to the EBSN, make sure that all the electrical connections are correct.
• Insert a fast-acting fuse of a value adequate to the maximum current absorption value of the bilge pump
on the power supply line.
• The joints between the cables leaving the ESBN and the electric system must be watertight or housed
inside an watertight container. The degree of tightness (IP rating) must be selected as required by the
work envinronment.
• The installation of the button option is only possible in conjunction with the Led option.
DIAGRAM OF CONNECTION TYPE
(1)
(2)
(2)
(1)
Optional
Watertight joints
(2)
EBSN 10-15-20 - REV001A
(1)
(2)
(2)
(2)
EBSN
INSTALLATION
SWITCH
FUSE
A
B
A
= Direct operation
of the pump
B
= operation by means
of EBSN
BATTERY
SHUNTING
SWITCH
PUMP
GB
9