AUTOMATIC procedure:
1 - Shut off power supply to control unit
2 - Position the gate at mid-travel.
3 - Press PROG/STOP button
4,5,6 - Switch on power to control unit by keeping the PROG./STOP button (part 6 of fig.1) pressed for at least 3 seconds.
Programming LED LD1 comes on. The same function can be obtained by holding the PROG./STOP button (part 9 of
fig.1) down, shorting the reset pins (part 15 of fig.1) for a moment, then releasing the PROG./STOP button when LED
LD1 comes on.
7 - Press pushbutton PED (or transmit using the second channel): the rolling gate should move to close.
8 - When the gate reaches the closing limit switch it should stop.
9 - After a short pause, the gate will move to open.
10 - When the gate reaches the partial opening point desired, press PED (or transmit using the second channel).
11 - After a short pause, the gate will move to close.
12 - When the gate reaches the closing limit switch it will stop.
13 - Led LD1 will go off, signalling the end of the programming procedure.