Electrical data • Caracteristicas eléctricas
Charactéristiques electrique • Dados eléctricos
Max. power input
absorbida y fusible recomendado
Consommation maximale
Potência máx. absorvida
Supply voltage (see type plate)
Tensión de entrada (ver etiqueta identificativa)
Alimentation électrique (voir plaque sign.)
Tensão de rede (ver placa indicadora)
Recommanded cable jacket diameter
Diámetro exterior del cable recomendado
diamètre recommandé pour la gaine du câble
Diâmetro recomendado do invólucro de cabo
Cable cross-section and recomm. fuse protection
Sección de cable y fusible recomendado
Section des fils et fusibles recommandé
Secção cabo e fusível recomendado
Contact loading
Carga del contacto
Pouvoir de coupure
Carga de contato
Maintenance • Mantenimiento • Entretien • Manutenção
x
x
x
x
x
x
x

0/5//...
VAC
P < 2,0 VA
Uac = ... ±10%
50 – 60 Hz
ø 5,8 - 8,5 mm
3 x 0,75 mm² / 5 x 0,25 mm²
3 x 0.0012 in.² / 5 x 0.0004 in.²
0,5 A *)
< 250 VAC / < 1,0 A
> 5 VDC / > 10 mA
x
Potential-free contact
 VDC
The alarm signal can be relayed via a
potential-free contact. The changeover
contact can be operated, e.g., in the fail-
P < 2,0 W
safe mode.
When operating voltage is being ap-
plied and the BEKOMAT 16 CV device
is functioning correctly, the alarm relay
U
= 24Vdc
0
is energized. The contact element (0.7
-10/+25%
- 0.8).
When there is no operating voltage or
in the case of a fault signal, the alarm
relay drops out. The contact element is
0.23 - 0.34 in.
open (alarm).
Externeral test button
Here, the normal test button function has
been extended for additional use outside
100 mA *) **)
the BEKOMAT 16 CV unit. This makes
it possible to discharge any condensate
in the unit by remote control, if required.
When the external contact closes, the
valve will open.
*) time lag
**) min. internal resistance of
Maintenance recommendation:
• Housing and valve should be cleaned
• Replace wearing parts once a year.
Set of wearing parts ( x )
BEKOMAT 16 CV
Functional test of BEKOMAT 6 CV
device:
• Press test button approx. 2 sec.
• Valve opens for condensate discharge.
Checking of alarm signal:
• Shut off condensate inflow.
• Press test button for at least 1 min.
• Red LED flashes (after 1 minute).
• Alarm signal is being relayed.
english
voltage source Ri> 12 Ohm
once a year.
XE KA16 201
BEKOMAT 16 CV