12. Operation
a) Turning on/off
• Push the trigger button (8) to turn on the product.
• The product turns off automatically after approx. 7 seconds of inactivity.
b) Activating/deactivating the target laser
• Push the button (2) to activate the target laser. The laser indicator (B) appears in the upper
left corner of the display.
• Push the button
c) Conducting measurements
• Push and hold the trigger button (8) and slowly scan the surface of the object. Point the IR
sensor (9) as vertically as possible at the measuring surface.
• While measuring the indicator SCAN (C) blinks in the upper half of the display. The middle of
the display shows the real-time reading (H). At the lower edge of the display, the maximum
reading (I) of the current measurement process is shown.
• Once you release the trigger button, the indicator HOLD (D) is shown in the upper half of
the display. The last registered reading is frozen on the display. The current measurement
process is now ended.
• If you start measuring again now, a new maximum reading will be calculated. The same
applies to the minimum reading.
d) Showing the minimum reading
Push the button MODE (4) once to show the minimum reading (I) of the current measurement
process at the lower edge of the display.
to deactivate the target laser. The laser indicator goes out.
35