7. Operation and fault analysis
Operation
Switch
Main beam
position
on
⊗ ⊗ ⊗ ⊗ ⊗
Pilot lamp
Pilot lamp
Main lamp
⊗ ⊗ ⊗ ⊗ ⊗
Main lamp
Main lamp
⊗ ⊗ ⊗ ⊗ ⊗
Flashing
mean beam
Flashing
main beam
Charging
OFF
⊗ ⊗ ⊗ ⊗ ⊗
OFF
Main lamp
Flashing
main lamp
Pilot lamp
Subject to alteration or supplement of the product series.
Cooper Crouse-Hinds GmbH
10
Flashg.
main beam
dimmed
flashing
⊗ ⊗ ⊗ ⊗ ⊗
Pilot light
LED display
on
pulsing red
⊗ ⊗ ⊗ ⊗ ⊗
none
⊗ ⊗ ⊗ ⊗ ⊗
Acc. to batt.
capacity
Acc. to batt.
capacity
⊗ ⊗ ⊗ ⊗ ⊗
only red LED
or none
Acc. to batt.
capacity
⊗ ⊗ ⊗ ⊗ ⊗
flashing
Acc. to batt.
capacity
Acc. to batt.
cap. or leading
LED pulsing
⊗ ⊗ ⊗ ⊗ ⊗
None
Acc. to batt.
capacity or
pulsing LED
Acc. to batt.
capacity or
pulsing LED
⊗ ⊗ ⊗ ⊗ ⊗
Acc. to batt.
capacity or
pulsing LED
Cause
Measure
Defect.
Replace pilot
pilot lp.
lamp
Function ok
None
Defect.
Replace
main lamp
main lamp
Function ok
None
Deep discharge
Recharge
protection active
function ok
Function ok
None
Defect.
Replace
main lamp
main lamp
Charging
None
completed
Defective
Searchlight
electronics
to be passed
for repair
Function ok
None
Function ok
None
Recharge
None or switch
period extended
to OFF pos.
to 28 hours