6.2.- Community operation / Step by step:
Community function (DIP 3 OFF).
One "start" opens; other "start" commands are not accepted in opening.
Step by step function (DIP 3 ON).
One "start" opens, another "start" stops the door, a third "start" closes, and if during the closing manoeuvre we activate
"start", the door stops and inverts the movement as far as the open door position.
6.3.- Optional Automatic:
In combination with DIP 4 ON.
-Optional automatic (DIP 5 ON)
if "Start" is received during the wait time, the door will close immediately.
-No optional automatic (DIP 5 OFF)
if "Start" is received during the wait time, the wait time is reset.
7.- Radio programming (for 433 Mhz Erreka RSD-001 trinary code only)
Radio programming must be done with the door closed.
The radio recordings for pedestrian and total opening are independent, and they may even correspond to different controls with
different codes.
7.1.- Total opening:
-Turn DIP 1to ON.
-Turn DIP 4 to ON. The memory is now open.
-Select the code on the control and press the channel to be recorded. LED DL2 will begin to flash.
-Turn DIP 4 to OFF.
-Turn DIP 1 to OFF.
7.2.- Pedestrian opening:
-Turn DIP 1to ON.
-Turn DIP 6 to ON. The memory is now open.
-Select the code on the control and press the channel to be recorded. LED DL2 will flash.
-Turn DIP 6 to OFF.
-Turn DIP 1 to OFF.
When the control code has been recorded, you will need to turn the switchboard off and on again
8.- Select the type of operation of the bright light.
8.1.- Early warning function.
By turning the DIP 2 to ON, the bright light comes on 3 seconds before the beginning of the manoeuvre.
8.2.- Lamp outlet
- DIP 6 to ON. The outlet to the lamp is flashing, owing to which a normal lamp can be fitted. The brightness function is
that of the panel.
- DIP 6 to OFF. The outlet is fixed, owing to which a bright lamp is required.
9.- Safety operation
- Opening Safety (connection terminals 4 and 5):
If the device is activated (photocell, band, ...) in the opening manoeuvre, the door stops and closes 20 cm.. In the closing
manoeuvre the said safety mechanism does not operate.
- Closing Safety (connection terminals 5 and 6):
If the device is activated (photocell, band, ...) in the closing manoeuvre, the door stops and inverts its movement until the door
is opened. In the opening manoeuvre the said safety mechanism does not operate.
In both cases, if the photo cell is cut during the waiting time, this period restarts.