Sanitization Procedure When Using Standard Storage Tank
14) Install an empty sanitizer cartridge into the postfilter head. Leaving the cold
water supply valve off (closed), open the storage tank shutoff valve and
allow the remaining water in the tank to discharge through the open tap.
When the flow stops, close the tap.
15) Close the shutoff valve on the empty storage tank. Remove the sanitizer
cartridge from the postfilter head and discard the water in it. Fill both
sanitizer cartridges 3/4 full with clean water. Add 1 teaspoon (5 ml) of
regular, unscented household bleach (6% sodium hypochlorite) to the
center of each cartridge using the 5ml dropper provided in the sanitizer
kit (Fig. 10) to chlorinate the water. Install the sanitizer cartridges into the
prefilter and postfilter heads.
16) Remove the module clip from the bracket manifold by squeezing the sides
inward and pulling the clip off (Fig. 11). Remove the RO module from the
center of the bracket manifold (Fig. 12). Install the sanitizer assembly to the
center of the bracket manifold (Fig. 13). Fasten the module clip to the
bracket manifold to secure the sanitizer assembly (Fig. 14). The clip must
snap into place on both sides (Fig. 15).