Err.45/
Err.46/
Eccentricity graph value display readout
Err.47/
error.
Err.48
Err.50/
Err.51/
Eccentricity graph current value cursor
Err.52/
plotting procedure error.
Err.53
Sonar readout error.
Err.54
Sonar value readout impossible.
Sonar readout error.
Err.55
Sonar values are insufficient for correct
measurement of eccentricity.
Lateral Sonar readout error.
Err.56
Lateral Sonar value readout impossible.
Lateral Sonar readout error.
Lateral Sonar values are insufficient for
Err.57
correct measurement of lateral
eccentricity.
Radial and lateral Sonar readout error.
Err.58
Radial and lateral Sonar value readout
impossible.
Radial and lateral Sonar readout error.
Lateral and radial Sonar values are
Err.59
insufficient for correct measurement of
radial and lateral eccentricity.
Err.65
Printer timeout
Err.66
Printer buffer error
Imbalance
Wheel slipping on the adapter because
incorrect
the BP system is at the end of travel or
with back
because of incorrect fitting of the tyre
centring
tie-rod
cones
Perform a new eccentricity measurement.
Perform a new eccentricity measurement.
1.
Position the eccentricity measurement sonar correctly before
performing the measurement.
2.
Check eccentricity sonar connections.
3.
Check the power supplies on the power board.
4.
Replace the eccentricity measurement sonar.
5.
Make sure that the wheel does not halt before completing at least
4/5 revolutions after the first braking impulse.
6.
Replace the computer board.
1.
Position the eccentricity measurement sonar correctly before
performing the measurement.
2.
Make sure that the wheel does not halt before completing at least
4/5 revolutions after the first braking impulse.
3.
Mount a wheel of medium dimensions (14"x5 ¾") and perform an
eccentricity measurement . If in these conditions error 55 no longer
occurs, this means that the wheel inertia causing the problem is such
as to half the wheel before having acquired the minimum number of
values necessary for reliable eccentricity measurement.
1.
Position the eccentricity measurement lateral sonar correctly before
performing the measurement.
2.
Check eccentricity lateral sonar connections.
3.
Check the power supplies on the power board.
4.
Replace the eccentricity lateral sonar.
5.
Make sure that the wheel does not stop before completing at least
4/5 revolutions after the first braking impulse.
6.
Replace the computer board.
1.
Position the eccentricity lateral sonar correctly before performing the
measurement.
2.
Make sure that the wheel does not stop before completing at least
4/5 revolutions after the first braking impulse.
3.
Mount a wheel of medium dimensions (14"x5 ¾") and perform an
eccentricity measurement . If in these conditions error 57 no longer
occurs, this means that the wheel inertia causing the problem is such
as to half the wheel before having acquired the minimum number of
values necessary for reliable lateral eccentricity measurement.
1.
Check points Err. 54
2.
Check points Err. 56
1.
Check points Err. 55
2.
Check points Err. 57
1.
Check that a printer is present.
2.
Check the code of the processor card.
3.
Check the printer <-> processor card connection.
4.
Run the printer test function.
1.
Reset the printer.
2.
Repeat the print function.
Mount the wheel in vertical position and push the sleeve up
against the wheel. If necessary, repeat locking/unlocking/locking
and perform the procedure again.
47