Einbauanleitung
Mounting instruction
Montagehandleiding
Instructions de montage
Istruzioni di montaggio
Use:
- The Poresta
Plus Ge slope element can be shortened by the
®
installer by up to 100 mm, with the exception of the drain side,
considering the geometry and installation height.
- The kind of utilization of the shower space (splash protection, move-
ment area, etc.) is to be considered.
- For installation of the slope element, a flat, clean, firm and vibra-
tion-less substrate suitable for cementing with Profi-Flex instant
adhesive is required.
- The slope element is generally wheelchair-accessible, using tiles
of a minimum size of 100 x 100 mm. When a fiberglass cloth is
incorporated in the tile adhesive bed it is also possible to use tiles of
a minimum size of 50 x 50 mm. .
- Suitable for indoor use only.
The installation instructions for the Geberit shower element
are to be observed.
The relevant working guidelines of all the trades involved
shall be observed.
1
When installing foundation elements (not included in the
scope of supply, see Figs. 6a to 8b) or a cast screed base
(see Figs. 6b to 7b) must be used. The height of the founda-
tion element/screed base is to be chosen according to the
difference in level between the unfinished floor and flooring
screed (also see installation examples).
2
Edge insulation strips are to be provided by the owner.
3
After the installation of the drain fitting, a leak test has to be
carried out.
4
Tile adhesive must always be applied to both sides.
The Geberit sealing set (not included in the scope of supply)
5
is to be used.
6
The manufacturer's processing instructions for the sealing
system shall be observed.
Example for installation with Poresta
Mounting height/finished floor level
Poresta
Plus Ge
®
2 layers of tile adhesive
Poresta
BF substructure element (X)
®
Installation example with screed base (Y):
Mounting height/finished floor level
Poresta
Plus Ge
®
1 layer of tile adhesive
Screed base (Y)
Poresta
Plus Ge
®
BF substructure element (X):
®
120 mm
- 50 mm
-10 mm
= 60 mm
120 mm
- 50 mm
- 5 mm
= 65 mm