EFOY COMFORT 80 Mode D'emploi page 89

Masquer les pouces Voir aussi pour COMFORT 80:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 94
Error message in the
display
Battery voltage low.
Please check battery
connection and charge
battery.
Battery voltage high.
If applicable, please
check additional
charging devices.
Please disconnect fuel
cartridge, shake
cartridge firmly and
reconnect. Restart
device at most 2 times.
Press OK for restart.
Page 88
www.busse-yachtshop.de | info@busse-yachtshop.de
Error
Solution
code
50
Please check the cabling and check
52
whether a suitable battery is
connected. Check the battery
voltage. If it is too low, please load
the battery with a battery charger.
Please check other loading devices
for defects also, e.g. alternator or
charge controller).
51
Please check the cabling and check
53
whether a suitable battery is
connected. Please check other
loading devices for defects also,
e.g. alternator or charge
controller.
72
Check the fuel cartridge connection
and, if necessary, check for any
contamination and remove it. Then
please perform a system reset
(max. two times). If the error still
occurs, please contact the hotline.
Contact details are provided in
chapter 1.2 "Contact details" on
page 49.
Errors and Solutions

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Comfort 140Comfort 210

Table des Matières