Operation
Battery protection
Permitted value
ranges for battery
protection
Battery protection
www.busse-yachtshop.de | info@busse-yachtshop.de
The EFOY fuel cell has automatic battery
protection, even when the EFOY fuel cell is
switched off. By default, battery protection
switches on when the battery voltage drops
below 11.2 V (for min. 60 seconds).
The battery protection function provides deep
discharge protection for the battery, even when
the fuel cell is switched off and the charging
function does not take over.
Factory
Min.
defaults
11.2 V
10.5 V
Max.
User-defined
value:
12 V
Page 79