BOS R254K-UUI-PR/RS/RE10-S4
Photoelectric Sensors
Function
In the case of a retroreflective
sensor(BOS R254K-...-PR10-...), the emitted light is
reflected back to the sensor by a reflector. Interruption of
the light beam by an object causes the switching
operation.
Through-beam sensors (BOS R254K-...-RS/RE10-...) are
sensors having separate transmitter and receiver units
which must be aligned with each other on opposite ends
of the detection range. When an object interrupts the light
beam, the receiver switches, i.e. the output signal
changes.
Display elements
LED 1 (operating status and communication)
Signal
Meaning
Static red
General error
Green alternating
IO-Link communication is active.
with LED off at ratio
The device is ready.
of 10:1, 1 s period
Static green
The device is ready.
LED 2 (indication/warning/teach/ping)
See document IO-Link configuration under
www.balluff.com on the product page.
Installation
CAUTION
Red light
If you look into the light beam emitted by the transmitter,
temporary blinding and irritation of the eyes is possible.
Use of Controls or adjustment or performance of
procedures other than those specified herein may result
in hazardous radiation exposure.
► Locate transmitter units so that it is not possible to
look into the light beam even during operation.
► Observe the instructions in this manual.
The sensor can be fastened with two M4 screws.
Plug outlet direction (example image of use with angled
connector (accessories)):
www.balluff.com
Electrical connection
1
2
4
Plug layout (top view of M12 plug on
3
BOS)
Pin Signal
1
L+ (Operating voltage +, SIO 10...30 V,
IO-Link 18...30 V)
2
I/Q (Digital input / digital output / analog output)
3
L− (Operating voltage −)
4
C/Q (IO-Link communication / digital output in SIO
mode)
Factory setting
– Mode: SIO mode
– Object recognition operating mode: Standard
– PIN 2: Push-pull switching output
– PIN 4: Push-pull switching output
Also see document IO-Link configuration under
www.balluff.com on the product page.
Shielding and cable routing
Cable length
For IO-Link operation, the maximum cable length is 20 m.
english