Hand dryer models B-700, B-7007, B-708, B-709 , and Hair dryer model B-731, 115V AC, 20 Amp, 50/60 Hz, Single Phase, cULus listed.
Hand dryer models B-700, B-7007, B-708, B-709 , and Hair dryer model B-731, 208–240V AC, 9–10 Amp, 50/60 Hz, Single Phase; cULus listed, VDE
approved, CCC approved, CE marked.
Distance from floor to bottom mounting screw holes of mounting base. (Dimension A)
Hand Dryer
Men's Washrooms .......................................................46''
Women's Washrooms ..................................................44''
Children's Washrooms, ages 3-9 ................................32''
Children's Washrooms, ages 9-12 ...............................36''
Children's Washrooms, ages 12-15 .............................40''
Children's Washrooms, ages 15-18 .............................44''
For the Handicapped ...................................................38''
*
Bobrick automatic hand dryers should be installed 15" (380mm) above any projection or horizontal surface which may interfere with the
operation of the automatic sensor.
1. Start installation of dryer by
removing cover. To loosen two
cover bolts, insert Allen
Wrench (provided with dryer)
into holes located on bottom
of cover on each side of air
intake grille. Make sure
wrench fits into head of cover
bolts and turn CLoCkWiSE
until bolts stop turning. When
cover bolts are screwed in all
the way, cover can be
removed.
1. Place mounting base on wall at the desired location of the installed
dryer. See recommended mounting heights above.
2. Use the mounting base or the template provided with dryer to mark
location of four mounting screw holes and hole for electrical wiring if
electrical supply is concealed in wall and will enter dryer from back
through mounting base.
NOTE: Surface-mounted electrical supply is attached to mounting base
in lower right corner. Flange of mounting base and bottom of cover are
notched in lower right corner to accommodate connection of electrical
conduit.
3. Drill four holes for 1/4" (6.4mm) diameter mounting bolts or screws
(not furnished by Bobrick).
4. Fasten mounting base securely to wall.
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT MUST BE INSTALLED BY A QUALIFIED LICENSED
ELECTRICIAN
1. Connect dryer to nearest distribution panel. Use wire as required by local electrical code. in the United States and Canada use No. 12 wire or larger.
2. Wiring instructions:
a. A fused means for disconnection in all poles must be provided in the fixed wiring in accordance with the wiring rules.
b.
For 115 Volt Dryers: Connect ground (earthed) wire to ground (earthed) terminal marked
and neutral or white wire to terminal marked N. A DEDICATED LINE IS REQUIRED FOR EACH 115 VOLT DRYER.
c. For 208–240 Volt Dryers: Connect ground (earthed) wire to ground (earthed) terminal marked
marked L (L1) and N (L2).
3. Secure electrical wire in strain relief clamp provided on mounting base.
Page 2
Electrical Characteristics
Recommended Mounting Heights
(117cm)
(112cm)
(81cm)
(91cm)
(102cm)
(112cm)
(97cm)
Removal of Cover
Installation of Mounting Base
Electrical Connection
Men's Dressing Rooms ...............................................72''
Women's Dressing Rooms ..........................................64''
Children's Dressing Rooms, ages 3-9 ........................45''
Children's Dressing Rooms, ages 9-12 .......................52''
Children's Dressing Rooms, ages 12-15 .....................58''
Children's Dressing Rooms, ages 15-18 .....................63''
2. To remove cover, place a
hand on each side of cover
and push up toward top of
dryer releasing cover from
studs at top of mounting base.
Lift cover off mounting base
by pulling forward at the
bottom and upward at the
same time.
10-15/64''
33/64''
260mm
S
13mm
7-43/64''
195mm
7/8''
22mm
Dia. Hole for
Between Wall Wiring
S
9-7/16''
Dimension
240mm
A
Finish Face of Floor
WARNING: TURN ELECTRICAL POWER SUPPLY OFF BEFORE MAKING
ELECTRICAL CONNECTIONS. DRYER MUST BE GROUNDED (EARTHED).
, the black or Hot wire to terminal marked L
and the 208-240 Volt wires to terminals
Hair Dryer
(183cm)
(163cm)
(114cm)
(132cm)
(147cm)
(160cm)
1-7/64''
28mm
S
10-3/8''
1''
265mm
25mm
8-43/64''
220mm
6-1/16''
155mm
3/16''
3/4''
5mm
S
19mm
1-3/8''
5/16''
35mm
8mm
15/32''
Flange Cutout for
12mm
Surface Wiring
3/4''
19mm

Publicité