Danger
If the insertion tool or the protective
hood of the machine does not
return to the home position, there is
a risk of injury from the exposed
insertion tool.
Do not lay down the machine
with exposed insertion tool.
Interrupt the processing
operation.
Remove the rechargeable
battery and/or disconnect the
mains plug from the power
supply.
Remove any jammed
splinters.
Check the functionality of the
protective hood of the
machine.
6
Exploded drawing and spare parts list
The corresponding information in respect of spare parts can be found on our homepage: www.mafell.com
5
Service and maintenance
5.1 Unit
The unit must be regularly dusted. The guides should
be cleaned with a vacuum cleaner.
Occasional spraying with machine oil maintains the
ease of movement of joints and guide pieces.
The storage place must be dry and frost-protected.
If the device fails despite diligent manufacturing and
test procedures, the repair must be carried out by an
authorised customer service station for MAFELL
products.
Danger
Only use MAFELL accessories and
spare parts. Components of which
their replacement has not been
described must be replaced by a
MAFELL customer service repair
shop.
5.2 Storage
If the unit is not used for a long period of time, it must
be cleaned carefully (see Chapter 5.1). Spray bright
metal panels with a rust inhibitor.