To fit Nose Tip Type 2 or Nose Extension, the 'T' Adaptor 1 must be replaced with Jaw Spreader Housing 9*.
Loosen Locknut 3 using 16mm AF Spanner.
Unscrew and remove 'T' Adaptor 1 together with 'O' Ring 2.
43
Fit Jaw Spreader Housing 9* together with 'O' Ring 10* (supplied with Type 2 Nose Assembly).
The Jaw Spreader Housing 9* must be tightened onto Head Piston 27 trapping Vacuum Sleeve 43 finally tighten
Locknut 3 against Jaw Spreader Housing 9*.
Items 9* and 10* refer to nose assembly components in Nose Tip table on page 12.
For other items in bold refer to the General Assembly drawing and Parts List on pages 24 and 25.
2
1
3
27
9*
10*
43
27
11