(12) Signal output 1/2
(13) Remote feeding
Remote feeding of the input and output
can be separately set by fuses. It is
possible to switch the remote feeding
voltage to the input or output by as-
sembling with the enclosed fuses
3 Removing lid and changing power supply
The CV range allows an easy removal and replacement of the lid integrated power
supply. Changing of the power supply lid allows the amplifier to be reconfigured
from mains to remotely fed supply. In service cases this is especially convenient:
The configuration of the amplifier with all plug-in modules, level settings as well as
switch setting are retained.
1. Loosen the screws and open amplifier.
2. Remove power supply connection be-
tween lid and amplifier board.
3. Hinge-out lid with one hand grip.
4. Place new lid, reconnect power supply
connection and close lid.